12
September 27, 2018
7082-153D
TREKKER INSERT
NOTICE:
In Canada when using a factory-built chimney
it must be safety listed, Type UL103 HT
(2100oF) [1149oC] CLASS “A” or conforming
to CAN/ULC-S629M, STANDARD FOR 650oC
FACTORY-BUILT CHIMNEYS.
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements:
-
Must be minimum 6 inch (152mm) inside diameter
of high temperature chimney listed to UL 103 HT
(2100°F) or ULC-S628.
-
Must use components required by the
manufacturer for installation.
-
Must maintain clearances required by the
manufacturer for installation.
-
Refer to manufacturers instructions for installation
-
This insert is listed to ASTM E 1509-12 Standard
and is approved for installation into listed factory-
built zero clearance fireplaces listed to UL 127
conforming to the following specifications and
instructions:
-
The original factory-built clearance fireplace
chimney cap must be re-installed after installing the
approved chimney liner meeting type UL 103 HT
requirements (2100°F) per UL 1777.
-
If the chimney is not listed as meeting HT
requirements, or if the factory built fireplace was
tested prior to 1998, a full height listed chimney
liner must be installed from the appliance flue collar
to the chimney top.
-
The liner must be securely attached to the insert
flue collar and the chimney top.
-
The air flow of the factory-built zero-clearance
fireplace system must not be altered. The flue liner
top support attachment must not reduce the air flow
for the existing air-cooled chimney system.
-
No dilution air is allowed to enter the chimney.
1.
Secure the fireplace damper in the open position. If this
cannot be accomplished, it will be necessary to remove
the damper.
2. Seal damper area of chimney around chimney
connector with a high temperature sealant or seal
insert against the face of the fireplace.
3. Both methods must be removable and replaceable for
cleaning and re-installation.
All modifications that can be made to a Factory Built
Fireplace can be made to a Masonry Fireplace.
In addition
DO NOT
remove any brick or mortar from the
existing fireplace.
G. Installation into a Masonry Fireplace
H. Prefabricated Metal Chimney
Risk of Fire!
Follow venting manufacturer’s clearances and
instructions when installing venting system.
WARNING
•
Removing floor of fireplace must not weaken
structure of firebox or reduce protection for
combustible materials.
•
Final approval of this installation type is contingent
upon the appropriate local authority having
jurisdiction.
WARNING