TREKKER INSERT

A. Design, Installation & Location 

Considerations

Install Guide

Getting Started

Marginal Location:

•  Below peak

Location NOT recommended:

•  Not the highest point of the roof

•  Wind loading possible

Multi-level Roofs

Windward 

Leeward

Recommended:

Outside Air Intake

on windward side

NOT recommended:

Outside Air Intake

on leeward side

Recommended Location:

•  Above peak

Recommended:

•  Insulated exterior chase 

in cooler climates

Recommended Location:

•  Above peak

•  Inside heated space

Location NOT recommended:

•  Too close to tree

•  Below adjacent structure

•  Lower roof line

•  Avoid outside wall

Marginal Location:

•  Wind loading possible

Figure 5.1

1.  Appliance Location

Since pellet exhaust can contain ash, soot or sparks, you 

must consider the location of:

•  Windows

•  Air Intakes

•  Air Conditioner

• 

Overhang, soffits, porch roofs, adjacent walls

• 

Landscaping, vegetation

•  Horizontal or vertical vent termination

2.  Floor Support

The supporting floor under the appliance must be able to 

handle the weight of the appliance, fuel load and the weight 

of the chimney.

Ensure that your floor will support these weights prior to 

installation. Add sufficient additional support to meet this 

weight requirement prior to installation. The weight of the 

appliance is 510 lbs. with a full load of fuel the max weight 

is 557 lbs.  

NOTICE:

 Check building codes prior to installation.

•  Installation MUST comply with local, regional, state and 

national codes and regulations.

•  Consult insurance carrier, local building inspector, 

fire officials or authorities having jurisdiction over 

restrictions, installation inspection and permits.

It is a good idea to plan your installation on paper, using 

exact measurements for clearances and floor protection, 

before actually beginning the installation. Location of the 

appliance and chimney will affect performance.

Consideration must be given to:

• 

Safety, convenience, traffic flow

• 

Placement of the chimney and chimney connector and 

to minimize the use of chimney offsets.

• 

Place the appliance where there will be a clear 

passage for a Listed chimney through the ceiling and 

roof (vertical) or through exterior wall (horizontal).

• 

Installing the required outside air kit will affect the 

location of the vent termination.

When locating vent and venting termination, the ideal 

location is to vent above roof line when possible. This 

minimizes the affects of wind loading.

WARNING

Risk of Fire.

Damaged parts could impair safe operation. Do NOT 

install damaged, incomplete or substitute components.

Summary of Contents for TREKKERI-MBKTREKKERI-CSBTREKKERI-PMH

Page 1: ...s not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appl...

Page 2: ...and Exhaust Connection 15 F Equivalent Feet of Pipe 16 G Pipe Selection Chart 16 5 Venting Systems 17 A Full Reline wit Outside Air Horizontal 17 B Full Reline with Outside Air Vertical 18 6 Applianc...

Page 3: ...0061PS094E EPA Certification 98 17 EPA Certified Emissions 0 74 g hr LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 682 39 428 HR BTU Input 16 396 50 775 HR Vent Size 3 4 or...

Page 4: ...ects or other reproductive harm For more information go to WWW P65Warnings ca gov G Combustible Materials Material made of or surfaced with any of the following materials Wood Compressed Paper Plant F...

Page 5: ...cient additional support to meet this weight requirement prior to installation The weight of the appliance is 510 lbs with a full load of fuel the max weight is 557 lbs NOTICE Check building codes pri...

Page 6: ...onsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home...

Page 7: ...ion and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the app...

Page 8: ...5mm 26 7 8 in 683mm 11 7 8 in 302mm 24 1 8 in 613mm 33 in 838mm 50 in 1270mm 34 1 2 in 876mm 45 in 1143mm 11 3 4 in 297mm 18 1 2 in 469mm Figure 8 2 Front View with Cast Panel Set 23 7 8 in 606mm 32 i...

Page 9: ...or choice must be added to this dimension Figure 9 1 Built in Appliance Rear Vent NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn...

Page 10: ...required Ember protection only If mantel depth is 10 inches or less than the height from the hearth to the bottom of the mantel is 39 3 4 inches Minimum Opening Dimensions Inches Millimeters A Height...

Page 11: ...ALTERED TO ACCOMMODATE AN INSERT IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE 250 2061 Heath Home Technologies 250 2061 5 5 in width x 2 in height NON AN...

Page 12: ...ll height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert flue collar and the chimney top The air flow of the...

Page 13: ...es and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in t...

Page 14: ...he demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation...

Page 15: ...hrough the chimney Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Considerations for successfu...

Page 16: ...00 feet 1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe...

Page 17: ...ombustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Fire Risk Inspection of Chimney Masonry chimney must be in good condition Meets minimum standard of NFPA 211 F...

Page 18: ...12 in 305mm min below 12 in 305mm min below NOTE In Canada this fireplace insert must be installed with a continuous chimney liner extending from the fireplace insert to the top of the chimney The ch...

Page 19: ...veling bolts if necessary to keep the insert level when installing Figure 19 3 Bend tabs down Shipped flat from the factory Included in Kit 1 bottom 1 trim front 2 trim sides 2 trim extensions Tools N...

Page 20: ...owered Phillips head screw driver 1 Remove contents from box being careful not to scratch or damage the cast trim pieces 2 Lay the surround set face down on protective covering to prevent scratching t...

Page 21: ...21 3 Back of Top Surround Back of Side Surround Screws Figure 21 1 Shown with trim installed on panel set 2 PIECE LOG SET INSTALLATION 1 Place the left log as shown There are 2 indentations in the bot...

Page 22: ...Key J Location Mounting of User Interface Shock hazard Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord...

Page 23: ...art Number OAK 3 Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 23 1 WARNING Products of combustion generate carbon monoxide and differen...

Page 24: ...24 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service 8 Reference Materials A Service Maintenance Log...

Page 25: ...25 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service...

Page 26: ...26 September 27 2018 7082 153D TREKKER INSERT Date of Service Performed By Description of Service...

Page 27: ...Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Panel Set G...

Page 28: ...te purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ De...

Reviews: