QuadroE1/T1 Manual I: Installation Guide
Configuring the Quadro E1/T1
QuadroE1/T1; (SW Version 3.2.x)
32
The Signaling Standard drop down list is available only in E1 mode and allows selecting
the connection signaling standard (ITU, ITU_T_2 or MELCAS).
In the table below, the page lists all timeslots. To configure the timeslots, select one or more
records from the table and press Edit functional button. This will open CAS Signaling Wiz-
ard where timeslot settings might be configured.
Fig. I-28: CAS Signaling Wizard - page 1
From the first page of the CAS Signaling Wizard, DID (Direct Inward Dialing) Service
might be enabled on the timeslot(s).
In User mode, the Quadro cannot route incoming calls from the E1/T1 trunk to extensions if
the timeslot in the trunk does not have DID service enabled. Incoming call routing takes
place according to the received caller ID. If the DID service is enabled on some timeslot(s),
an incoming call on these timeslots may be routed to the specified extension, the Attendant,
or the routing client (depending on the configuration).
Please Note:
The timeslot with DID service enabled cannot be used for outgoing calls.
In Network mode DID service does not limit the Quadro functionality but a timeslot with en-
abled DID service cannot be used for incoming calls.
Please Note:
The CO/private PBX must support the DID service, if it is to be configured on
the QuadroE1/T1.