HEALTHCARE
HEADSET SYSTEM
Multiple systems in the same premises
It’s quite normal to use multiple systems in the same premises - and
systems won’t interfere with one another. But if you swap headsets
between systems, thus taking a headset from system A and registering it
to system B, you should clear its registration from system A; otherwise the
headset may pick up audio from both, because it could remain
registered to both.
If you move a headset from system A to system B follow
this procedure:
1
Go to system A, make sure all the headsets used
on the system are gathered, including the one(s)
you want to move to system B. Remove the battery
from each headset.
2
Put the Base into registration mode.
Leave it for 2-3 minutes. This process will
delete all the headsets from the Base. Press
registration button again.
3
Put the battery back into each of the headsets you want to keep on
system A, then go through the normal registration process again, as
if for the first time to register the remaining headsets back onto system A.
4
When the system A registration is completed, then go to system B and
add the headset(s) to that system following the normal registration
procedure.
Never have more than one system in registration mode at the same time.