Setting the Pump Jack Poles:

1) Space poles uniformly not more than 7 feet on center when 
using 2 inch thick nominal walk planks, 9 feet on center when 
using 2 inch undressed lumber or 11 feet on center when us-
ing aluminum walk planks.  Always support aluminum walk 
planks longer than 12 feet at both ends and in the middle of 
the walk platform.  Poles shall not exceed 30 feet in height.  2) 
Using rigid steel triangular bracing, attach a brace to the top 
of each pole by loosening the wing nut on the brace’s clamp-
ing mechanism and sliding the clamping plates over the wood 
pole so that the pole’s seam faces the carriage bolt.  Then 
tighten at the desired height.  Nail clamp to pole.  3) Position 
the poles along the work wall and secure in place.  Always use 
triangular steel pump jack braces.  The round bar of the brace 
should be fastened to the work wall at right angle to the walk 
plank.  The angle bar of the brace is then fastened to the right 
or left as desired.  Space between the brace arms is 32 inches, 
enabling installation on studs 16 inches apart.  The seam of 
the pole must face the work wall.  4) All poles must bear on a 
fi rm foundation or mudsill.  Install a pole anchor, then insert 
pole and secure in place.  Or, using a 2”x10” square piece of 
lumber remove enough dirt to insert board creating a fi rm level 
foundation.  Secure pole in place by blocking all four sides with 
2x4’s and nailing in place.  5) Install triangular steel bracing 
at the bottom of the pole to prevent movement.  6) Additional 
pump jack braces must be installed vertically along each pole 
no more than 10 feet apart.

Installing  Pump  Jack,  Workbench,  Guardrail  and  Walk 
Planks:
Pump Jack: 

Attach the pump jack to the pole with the platform 

arm facing the work wall by removing the round pin and roller, 
crank and square pedal.  Place the pump jack over the pole 
and reconnect parts.  Secure all parts by inserting cotter pins 
and bending one leg 90 degrees.  Open pump jack by fully 
extending the platform arm.  

Walk Planks: 

Place walk plank 

onto platform arm.  All scaffold planks must rest securely onto 
the platform arm and extend no less than 6 inches and no more 
than 12 inches over the support arm.  When overlapping of 
platforms is required there must be a minimum of 12 inches 
of overlap.  The support arm must be centered between the 
overlapping  walk  planks  and  be  secured  from  movement.  

PUMP JACK 

SYSTEM AND ACCESSORIES