Qualisys reserves the right to change specifications without notice.
For a complete description of
the Long Range Active Marker, please refer to the technical reference.
Control box
114 x 107 x 34 mm, 330 g
Battery pack
114 x 107 x 34 mm, 1 m cable, 450 g
Spherical marker
50 mm in diameter, 5 m cable, 250 g
IR eye
30 x 40 x 15 mm, 5 m cable, 220 g
Total weight of a long range marker calibration kit
2 kg
Frequency range
1–200 fps
Flash time
325 m
Maximum trigger distance
At least 100 m
Battery time, 50 fps, 4 markers
18 hours
Battery time, 100 fps, 4 markers
9 hours
Time to charge battery
3 hours 30 min
Nominal battery capacity
2200 mAh, 14.8 V
Input power range
10-18 VDC
SPECIFICATIONS
HOW TO CONNECT:
1. Connect the spherical markers to the connections MARKER 1 –
MARKER 4 on the control box. Part of the thread is still visible when it
is connected correctly.
IMPORTANT: The markers must be connected before the control box is
turned on to operate with full intensity. The spherical markers are delivered
with the cable attached. Do not remove - it is difficult to reconnect.
2. Connect the battery pack or power supply to the BATTERY/12 VDC
connection. Make sure to fully charge the battery before first time use.
3. Connect the IR eye to the IR IN/SYNC IN connection.
4. Attach a protective cover to any unused connection to keep the box splash-proof.
5. Start the control box with the ON/OFF button.
IMPORTANT: The button must be pressed and held until the POWER/BATT LOW LED is lit green. When switching off the
control box press and hold the button until the POWER/BATT LOW LED is turned off.
6. The Long range active marker is now ready for use.
7. Activate it in QTM by selecting “Long Range Active Marker” as “Marker type” on Camera system/Camera settings/
Advanced in the Project Options.
QUALISYS
Qualisys Europe
Gothenburg, Sweden
qualisys.com
Qualisys Americas
Chicago, USA
Qualisys Asia Pacific
Shanghai, China