Step 5: Attach top panel [A] to the unit as shown in Fig. E with 3 

KD screws [W].  See Fig. E.  

Fig. E

Step 6: Tighten all KD screws.

FIREPLACE INSERT INSTALLATION:

The fireplace insert can be installed after the mantel has been fully 

assembled.

WARNING: Make sure the fireplace insert controls are in the 

OFF position and the unit is NOT plugged in.

Step 1: Carefully place the INSERT in the unit opening.  The front 

of INSERT should be flush with the front of the mantel.  Carefully 

lift the INSERT into the mantel until the top stopper is against the 

mantel.

Fig. F     

Step 2: Attach 3 Mounting Clips [U] to the top side of insert with 

3 Medium KD screws [R]. Attach 2 Mounting Brackets [V] to the 

bottom of insert with 2 Short KD screws [T]. See Fig F.

Step 3: Move assembled unit to desired location. Unit should not be 

positioned in area exposed to direct sunlight.

OPERATION

After reading complete instructions, confirm all controls on fireplace 

are in the OFF position. Plug the fireplace into a 15AMP/120Volt 

outlet. If the cord does not reach, you may use an extension cord 

rated for a minimum of 1875 WATTS. Once the fireplace insert has 

been properly connected to a grounded electrical outlet, it is ready 

to operate.

OPERATION BY THE CONTROL PANEL 

The controls are located behind the 2 front covers at the top right 

and left corners of the insert, and can be accessed by gently push-

ing the bottom of the covers.

O/I

: Press this button for main power and flame effect. The indica-

tor light will turn on. See below for other control switches.

750W:

 For low heat function - Press this switch while the O/I switch 

is in the on position for low heat. The indicator light will turn on.

1500W:

 For high heat function - Press this switch while the O/I 

switch  and the 750W switch are in the on position for high heat. 

The indicator light will turn on.

Temperature Control: 

To adjust the temperature to your individual 

requirements, turn the temperature control dial to the right (clock-

wise) to increase the desired temperature and to the left for lower 

temperature. This temperature control dial can only be used while 

the O/I switch and 750W & 1500W switches are in the ON position.

Dimmer Control Knob:

 Turn the dimmer dial clockwise or counter 

clockwise to get the desired flame intensity. The dimmer switch can 

only be used when the O/I switch is in the on position.

Note:

 When the O/I switch is turned off, all other heater functions 

will stop even though the switches may be in the on position. 

 

Summary of Contents for MM910-33ECN

Page 1: ...never the fireplace is left operating and unattended 4 Always unplug fireplace when not in use 5 Do not operate any electric fireplace with a damaged cord or plug or after the heater malfunctions has...

Page 2: ...the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available A 15 AMP circuit is required...

Page 3: ...all panels are assembled Step 1 Attach 13 plastic connectors X to Panel C D E F and G with 26 KD screws W as shown in Fig A 2 KD screws W for each plastic connector Attach 2 wood connectors S to pane...

Page 4: ...ly connected to a grounded electrical outlet it is ready to operate OPERATION BY THE CONTROL PANEL The controls are located behind the 2 front covers at the top right and left corners of the insert an...

Page 5: ...att type E 12 bulbs Step 4 Loosen remove and replace the burnt out bulb s Step 5 Set the log set bed back into place and re attach the screws Step 6 Close the glass window and re attach the screws Ste...

Page 6: ...See Fig G Fig G Fig H 3 Attach the SMALL L BRACKET and lock in place with SCREWS as shown in Fig H CLEANING To clean unit first turn off controls on unit and unplug the unit from power source To clea...

Page 7: ...the unit This warranty is void if in the opinion of Quality Craft the unit has been tampered with altered misused damaged abused or used with the wrong power source Light bulbs are not covered by this...

Reviews: