4
Step 5: Attach top panel [A] to the unit as shown in Fig. E with 3
KD screws [W]. See Fig. E.
Fig. E
Step 6: Tighten all KD screws.
FIREPLACE INSERT INSTALLATION:
The fireplace insert can be installed after the mantel has been fully
assembled.
WARNING: Make sure the fireplace insert controls are in the
OFF position and the unit is NOT plugged in.
Step 1: Carefully place the INSERT in the unit opening. The front
of INSERT should be flush with the front of the mantel. Carefully
lift the INSERT into the mantel until the top stopper is against the
mantel.
Fig. F
Step 2: Attach 3 Mounting Clips [U] to the top side of insert with
3 Medium KD screws [R]. Attach 2 Mounting Brackets [V] to the
bottom of insert with 2 Short KD screws [T]. See Fig F.
Step 3: Move assembled unit to desired location. Unit should not be
positioned in area exposed to direct sunlight.
OPERATION
After reading complete instructions, confirm all controls on fireplace
are in the OFF position. Plug the fireplace into a 15AMP/120Volt
outlet. If the cord does not reach, you may use an extension cord
rated for a minimum of 1875 WATTS. Once the fireplace insert has
been properly connected to a grounded electrical outlet, it is ready
to operate.
OPERATION BY THE CONTROL PANEL
The controls are located behind the 2 front covers at the top right
and left corners of the insert, and can be accessed by gently push-
ing the bottom of the covers.
O/I
: Press this button for main power and flame effect. The indica-
tor light will turn on. See below for other control switches.
750W:
For low heat function - Press this switch while the O/I switch
is in the on position for low heat. The indicator light will turn on.
1500W:
For high heat function - Press this switch while the O/I
switch and the 750W switch are in the on position for high heat.
The indicator light will turn on.
Temperature Control:
To adjust the temperature to your individual
requirements, turn the temperature control dial to the right (clock-
wise) to increase the desired temperature and to the left for lower
temperature. This temperature control dial can only be used while
the O/I switch and 750W & 1500W switches are in the ON position.
Dimmer Control Knob:
Turn the dimmer dial clockwise or counter
clockwise to get the desired flame intensity. The dimmer switch can
only be used when the O/I switch is in the on position.
Note:
When the O/I switch is turned off, all other heater functions
will stop even though the switches may be in the on position.