Model EQ10
Installation, Operation and Maintenance
Page 8
Rev. 11/30/2020
EQ
10-IOM-Q.
doc
IMPORTANT
:
A
FTER WIRING HAS BEEN COMPLETED
,
TEST OPERATION OF
P
OWER
U
NIT
&
O
VERHEAD
L
IMIT
SWITCH
.
W
HILE RAISING LIFT
,
OPERATE
O
VERHEAD
S
HUTOFF
B
AR
.
P
OWER
U
NIT
M
OTOR SHOULD STOP
WHEN
S
HUTOFF
B
AR IS RAISED
.
C
OLUMN
D
ECAL
P
LACEMENT
43) Clean the surface of the columns before placing
the decals.
44) Apply the Safety Decals (Pg. 3) below the lock
clevis on the power column and the Logo Decal
48” above the base plate on the idler column.
Fig 12
.
Fig. 12 – Safety & Logo Decal Placement
F
INAL
A
DJUSTMENTS
H
YDRAULICS
45) Lower the lift to the floor and raise the lift
approximately one foot.
46) Start with Idler side first. Slowly and carefully
loosen the bleed plug on top side of the cylinder
just enough to allow the entrapped air to escape.
Repeat for power side.
47) Raise lift 6 inches. Repeat previous step until no
air comes out of the cylinders.
48) Pressure test hydraulic system. Energize power
unit, raise lift to full rise and continue to run
motor for additional 10 seconds. (NOTE:
pressure relief will make a high pitch squeal
sound for these 10 seconds.) Check hydraulic
system for leaks.
49) Energize power unit again for 10 seconds. With
a clean rag, wipe down both cylinder rods. (The
cylinders are shipped with a small amount of
clear anti-corosive lubricant that will be forced
out through the wiper when the lift reaches full
rise.)
If lubricant is not wiped clean from the
cylinder rod, the cylinder will apear to be
leaking
.
S
YNCHRONIZING
C
ABLES
50) Raise lift and ensure carriages lower into same
lock position.
51) Adjust synchronizing cables so the tension is
equal in both cables and carriages are firmly
sitting on locks.
52)
Cycle lift to ensure that latches operate
simultaneously.
L
OCK
R
ELEASE
C
ABLE
53) Raise lift to a lock position but don’t set into the
lock. Pull and release Power Column lock
release handle while watching Idler Column lock.
IMPORTANT: I
F IDLER SIDE LOCK PAWL DOES NOT
FULLY DISENGAGE
,
DAMAGE MAY RESULT TO IDLER
SIDE CARRIAGE AND OR CABLE SYNCHRONIZING
SYSTEM
.
Adjust cable tension by adjusting
location of threaded cable lug on the mounting
tabs. Cable clamps may need to be loosened.
54) After both locks fully disengage when the Power
Column lock release handle is pulled down,
tighten all clamps to secure lock release cable
assembly.
55) Install both plastic lock covers ensuring lock
cable assembly is routed thru formed guides in
the covers. Replace lock release knob. Ensure
lock release handle still disengages both locks
with the lock covers in place.
F
INAL
C
HECKOUT
P
ROCEDURE
56) Demonstrate the operation of the lift to the
owner/operator/employer using a typical vehicle
and review correct and safe lifting procedures
using the
Lifting It Right
booklet as a guide.
57) Return all provided literature (including this
manual) to the literature pack envelope and
deliver the envelope to the
owner/operator/employer.
58) Complete the online warranty registration (refer