7-70
Field
–
Replaceable Units (FRUs)
501510 Rev. S
7.22.1
Fixed Slot Removal
1.
Remove the Carriage Assembly from the RLS as described in Section 7.7.1.
2.
Using a No. 1 Phillips screwdriver, remove the two Fixed Slots mounting screws.
Remove the Fixed Slot. Repeat this step for the remaining Fixed Slots.
7.22.2
Fixed Slot Replacement
1.
Position the Fixed Slot in the library so that the end of the Fixed Slot with the
notches is facing up.
2.
Align the mounting holes in the Fixed Slot with the threaded holes in the RLS
and using a No. 1 Phillips screwdriver, replace the two pan-head screws that
were removed earlier. Repeat this step for the remaining Fixed Slots.
3.
Reinstall the Carriage Assembly into the RLS as described in Section 7.
4.
Proceed to Section 7.24 to calibrate the RLS.
7.23
Air Filter
P/N 510096-01-9
Front Panel/Door
Right Side Slot
Left Side Slot
Air Filter Element
Center Rib
Notch in
Air Filter
Lip in
Front Panel/Door
Figure 7-45 Air Filter with the Front Panel/Door Open
Summary of Contents for RLS-4470
Page 1: ...RLS 8000 Tape Library Technical Service Manual 501510 Rev S...
Page 2: ......
Page 14: ...xiv 501510 Rev S This page left blank intentionally...
Page 16: ...1 2 Introduction 501510 Rev S Table 1 1 Applicable Documents...
Page 20: ...1 6 Introduction 501510 Rev S This page left blank intentionally...
Page 23: ...501510 Rev S Description and Theory of Operation 2 3...
Page 34: ......
Page 50: ...3 16 The Operator Interface 501510 Rev S This page left blank intentionally...
Page 64: ...4 14 The Maintenance Menu 501510 Rev S This page left blank intentionally...
Page 65: ...501510 Rev S The Private Menu 5 1 5 The Private Menu...
Page 69: ...501510 Rev S The Private Menu 5 5 10 Close the Front Panel Door...
Page 188: ...8 10 Firmware Updating 501510 Rev S Figure 8 7 Properties Screen...
Page 205: ...501510 Rev S RLS Expansions 9 13 This page left blank intentionally...