FUNCTION OPERATION AND DESCRIPTION
FUNCTION OPERATION AND DESCRIPTION
Reset(RESET)——Menu No.41
This function is to set Menu and channel initialization. You can set the desired
function and parameter after reset.
FUNCTION OPERATION AND DESCRIPTION(The following description is without
voice prompt.)
Displays When Power On(PONMSG)——Menu No.38
1. In frequency or channel mode, press Menu+38, the LCD displays:
2. Press key Menu, and then press key ▲ or ▼ to choose,the LCD displays:
FULL:Full frequency character display
MSG:NUT logo display.
3. After setting, press key Menu to confirm, and then press key PTT or Exit to standby.
4. Setting FULL, the LCD displays: ; Setting MSG, the LCD displays:
This function can set the display mode when power on.
The operation steps are as follows:
Call End Warning Tone(ROGER)——Menu No.39
1. In frequency or channel mode, press Menu+39, the LCD displays:
2. Press key Menu, and then press key ▲ or ▼ to choose,the LCD displays:
OFF: OFF
ON: ON
3. After setting, press key Menu to confirm, and then press key PTT or Exit to standby.
This function is to make receptor hear a beep when conversation ends.
The operation steps are as follows:
007
WELCOME
FUNCTION OPERATION AND DESCRIPTION(The following description is without
voice prompt.)
Dual-watch Operation(TDR-AB)——Menu No.40
1. In frequency or channel mode, press Menu+34, the LCD displays:
2. Press key Menu, and then press key ▲ or ▼ to choose,the LCD displays:
There are three options:
OFF:“▲”or “▼”will glitter on transmitting frequency band.
A band to transmit in dual-watch code
B band to transimit in dual-watch code
Example: The LCD displays:
① Choose A means 465.575MHz is the transmitting frequency band, 136.225MHz is the
receiving frequency band.
② Conversely, choose B means 136.225 MHz is transmitting frequency band, 465.575MHz is
receiving frequency band.
3. After setting, press key Menu to confirm, and then press key PTT or Exit to standby.
The function is to set A band or B band is transimit band when in dual-watch state.
It also can be used for cross band receiving and transmitting.
The operation steps are as follows:
TDR-AB
OFF
40
40
TDR-AB
A
465.575
136.225
CT
PONMSG
FULL
38
38
PONMSG
MSG
ROGER
OFF
39
39
ROGER
ON
43
44
Summary of Contents for TG-007
Page 1: ...USER S MANUAL TG 007 0700...