background image

17

AC-JSB-4

STEP SYSTEMS

Junction Box

Materials

Lid & Box

• High impact, corrosion resistant thermoplastic

• Weatherproof

• 1/2” UL approved, CSA Certified round cable 

liquid-tight strain

  relief connectors

• 1-1/2” terminal adapter hub 
Gasket

• Flexible PVC
Screws

• Brass

Warranty for Defects in Material and Workmanship

• Junction Boxes - 3 Years

STEP SYSTEMS

Control Panel

AC-CP-S-C-T

Specifications

Enclosure 

• Measures 10x8x4 inches (25.40x20.32x10.16 cm).  

NEMA 4X (ultraviolet stabilized thermoplastic with re-

movable flanges for outdoor or indoor use).

• Magnetic Motor Contactor controls pump by switching 

hot electrical lines

• HOA Switch for manual pump control (mounted on cir-

cuit board)

• Float Switch Terminal Block

• Alarm and Control Fuses

• Programmable Timer with separate variable controls al-

lows for setting the on and off times from .05 seconds to 

30 hours.

• Circuit Breaker provides pump disconnect and branch 

circuit protection

Power Supply

• Pump-120/208/240V, 7-15FLA

• Alarm-120V
Standard Alarm Package

• Red Alarm Beacon provides 360 visual check of alarm 

condition

• Exterior Horn Test/Normal/Silence Switch allows alarm 

horn to be silenced and testing of horn and light to en-

sure proper operation of alarm system

• Horn Silence Relay automatically resets alarm after 

alarm condition has been resolved (mounted on circuit 

board)

Warranty for Defects in Material and Workmanship

• Control Panel - 3 Years

Summary of Contents for AeroCell ATS-SCAT-8-AC-C500

Page 1: ...STWOOD KY 40014 FAX 502 992 8249 www quanics net CLASS I NSF STD 40 WASTEWATER TREATMENT SYSTEM OPERATION MAINTENANCE MANUAL MANUFACTURED PRODUCTS BY QUANICSTM FIXED FILM MEDIA WASTEWATER TREATMENT SY...

Page 2: ...c Tank 3 Section 2 0 A300 8 Series Effluent Filter 3 Section 3 0 Dosing Tank 4 Section 4 0 Filtered Pump Vault 4 Section 5 0 Controls Pumps Floats 4 Section 6 0 Treatment Module 4 Section 7 0 Recircul...

Page 3: ...s utilizing fixed film media The module s consist of a fiberglass tank s containing a pre determined amount of media Ef fluent is sprayed over the media utilizing specialized spay nozzles This patente...

Page 4: ...able float is down the pump will need to be activated manually by switching the HOA switch in the control panel to HAND 6 While the pump is running observe the spray nozzles in the treatment module fo...

Page 5: ...ed 2 Remove the filter panel Rinse the filter plates with fresh water making sure all septage is rinsed back into the tank The filter plates should be cleaned until all slots are open and free of de b...

Page 6: ...ocated at the proper level When the ball float is at its lowest position it should be located equal to or just above the on position of the timer enable float figure 1 2 Check that the design recircul...

Page 7: ...idge has been removed b Check the septic tank to see if it appears normal If not check with the PROPERTY OWNER to determine what inappropriate materials might have been added to the waste stream 3 Rec...

Page 8: ...ory personnel Follow these safety precautions when performing any excavation or construction work Follow all construction safety procedures during installation Follow electrical safety procedures duri...

Page 9: ...anics net autocad htm 750 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio...

Page 10: ...anics net autocad htm 1250 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio...

Page 11: ...ics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 500 gallons per day 85...

Page 12: ...W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 750 gallons per day 138ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate...

Page 13: ...W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 1250 gallons per day 223ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate...

Page 14: ...T 886 BC C1250 1250 12 3 223 5 61 2500 1250 76 8 15 3 81 ATS SCAT 888 AC C1500 ATS SCAT 888 BC C1500 1500 12 3 255 5 88 3000 1500 76 8 15 3 98 The Zabel A300 8x18 VC model effluent filter is used in s...

Page 15: ...n Outlet hub accepts 4 or 6 SCH 40 outlet pipe All Zabel Filters accept SmartFilter alarm switch GPD Maximum Gallons Per Day FS Filtration Size Warranty for Defects in Material and Workmanship Effluen...

Page 16: ...3M 300 V SJOW jacketed 2 wire with ground Materials of Construction 300 grade stainless and cast iron Discharge 1 1 2 Warranty for Defects in Material and Workmanship All components 3 Years STEP SYSTE...

Page 17: ...ears PDS GT 2 0 STEP SYSTEMS Float Tree AC FT 3 Materials Pipe 1 5 or 2 SCH 40 PVC 1 5 or 2 PVC flex tubing True Union Ball Valve PVC Plastic Double block full port design 1 5 or 2 slip slip hubs Fitt...

Page 18: ...electrical lines HOA Switch for manual pump control mounted on cir cuit board Float Switch Terminal Block Alarm and Control Fuses Programmable Timer with separate variable controls al lows for setting...

Page 19: ...harge Assembly 2 Years Float Valve Assembly 2 Years ATS GRD 100 80 20 N Materials Risers and Lids High density non corrosive polyethyl ene plastic Stainless steel screws Neoprene gasket IMPORTANT When...

Page 20: ...19 Wiring Schematics...

Page 21: ...20 Consecutively Serial Numbered Data Plates Maintenance Sticker...

Page 22: ...Y OWNER Responsibilities The PROPERTY OWNER confirms that he has read and understands the AeroCell Bio COIR Operation Manual and agrees to operate the QUANICS AeroCell Bio COIR Advanced Treatment Syst...

Page 23: ...m the date of installation pumps for a period of three years from the date of installation and AeroCell Bio COIR foam for a period of ten years from the date of installation Failed warranted parts sha...

Page 24: ...X 1520 PHONE 502 992 8200 6244 OLD LAGRANGE ROAD 1 877 QUANICS CRESTWOOD KY 40014 FAX 502 992 8249 www quanics net Treatment system service provider 082707 326 E n g i n e e r i n g Water S o l u t i...

Reviews: