1. Safety precautions

Read  the  operational  manual  carefully  before  switching  on  the 

regulator. Do not repair or maintain the regulator yourself.

1.1. Electric safety

Electric safety:

•  operate the device with damaged wiring insulation;
•  operate the device without protective grounding;
•  touch bare cables and electrical connections by your hands;
•  operate the regulator in direct contact with liquid (rain, snow 

etc.), as well as under the conditions of increased humidity;

•  use a one-phase network to connect voltage regulators with-

out a earthing.

The one-phase Quant voltage regulator goes on sale in a state 

that complies with safety regulations.

Do not disassemble the regulator. Do not remove the protective 

elements of the housing.

1.2. Fire safety

Do not operate the regulator near flammable materials.
Do not block the ventilation openings, do not operate the regula-

tor in a confined space (box, cabinet), i.e. in conditions of insuffi-

cient ventilation.

Do not operate the regulator in direct sunlight or in atmospheric 

precipitation.

1.3. General safety precautions

•  keep children away from the regulator, even is it’s off;
•  do not cover the regulator with foreign items during operation 

(an emergency or ignition of foreign items may occure);

•  do not allow foreign items to get inside the regulator;
•  it is forbidden to connect a constant load that exceeds the 

maximum load of the voltage regulator;

•  if  the  regulators  have  been  stored  or  transported  at  a  tem-

perature lower than 0°c, they must be left in a room at room 

temperature for at least 5 hours before installation;

•  if the input wire is constantly heated due to high current, tight-

en the stabilizer input terminal screw. if the input wire contin-

ues to heat up, make sure that it has sufficient cross-section 

for the regulator power  according to the wiring material spec-

ification;

•  install/remove regultaros only when the input circuit breaker 

is switched off.

QUANT-7  

 Automatic voltage regulator, one-phase

 

 

Summary of Contents for QUANT-7

Page 1: ...QUANT 7 Made in Ukraine 27 1 22049061 001 2021 OUR MERIT SAFE VOLTAGE Automatic voltage regulator one phase Operation manual...

Page 2: ...ect outlet in the house or in the perfect regulator Therefore in fact the development of QUANT regulators made anew from circuitry algorithms and software list of equipment to design and construction...

Page 3: ...3 QUANT 7 Automatic voltage regulator one phase Find out all about QUANT stabilizers on the channel https www youtube com channel UCWVXbv4Spwr5yUb U9fvMWw OPERATION MANUAL...

Page 4: ...ations 8 3 1 Extended specification and technical specifications 9 4 Scope of delivery 10 5 Device and principle of operation 10 6 Installation and connection 13 7 Regulator operation 16 8 Regulator o...

Page 5: ...5 5 QUANT 7 Automatic voltage regulator one phase...

Page 6: ...ined space box cabinet i e in conditions of insuffi cient ventilation Do not operate the regulator in direct sunlight or in atmospheric precipitation 1 3 General safety precautions keep children away...

Page 7: ...or before the overvoltage pulse reaches the load Most dangerous situations are solved without switching off the regulator so that the load receives a clean filtered voltage for phase 220V 230V 50Hz an...

Page 8: ...erating frequency range Hz 45 50 Operating temperature range 5 40 Humidity range 0 80 Delay before switching on sec 6 Mounting method Hinged Protection index 20 Cooling Forced Low noise Number of phas...

Page 9: ...tage regulator limits the input and output current taking into account double overload If the value is ex ceeded by 200 of the nominal power the regulator will turn off in 1 second Thanks to the limit...

Page 10: ...ing from the grid The input voltage from the grid is fed through the input circuit breaker to the input of the regulator circuit initially supplies a low power auxiliary power supply and the motherboa...

Page 11: ...or its input and output filters reactive pow er compensator for normal operation mode which includes any surges and spikes in voltage within the acceptable regu lation range of the device overvoltage...

Page 12: ...12 REGULATOR CIRCUIT QUANT 7 Automatic voltage regulator one phase...

Page 13: ...fixed It is desirable to use special equipment or check the site plan check the site plan If you are not sure if there are any power lines in this If you are not sure if there are any power lines in...

Page 14: ...on the back panel fit into the slots of the suspension bracket Check the accuracy of the fitting by trying to move each regulator slightly holding back from a possible fall left right and pulling dow...

Page 15: ...15 15 VOLTAGE REGULATOR INSTALLATION CHART N L Electricity meter 220V socket Stabilizer Automaton QUANT 7 Automatic voltage regulator one phase...

Page 16: ...ansformers in the presence of both smooth and sudden mains voltage spikes at the regulator input as long as they are within the allowable regulation range the output voltage of the regulator remains u...

Page 17: ...vailable as soon as the device is turned on They are switched with the Left and Right buttons below the screen left and right buttons Information screens without settings MAIN SCREEN It is displayed b...

Page 18: ...hin 3 and switching from 220V to 230V and back It is also possible to test coolers set the speed to check the quality of the coolers the absence of unnecessary noise To enter the second level menu lon...

Page 19: ...RPMs To exit the menu press the middle button again You can safely move further on the menu the device will return the cooling sys tem to normal mode The value is not saved SCREEN NO 7 TECHNICAL SECT...

Page 20: ...on SCREEN NO 11 MAXIMUM INPUT VOLTAGE The maximum allowable voltage at the input of the regulator If this threshold is exceeded the regulator will shut down SCREEN NO 12 TURN ON DELAY Shows how many s...

Page 21: ...Changing this parameter may cause the regulator to shut down immediately after switching on if the mains voltage is steadily increased It is not recommended to change this parameter without consulting...

Page 22: ...r voltages In addition it is guaranteed that neither one nor the other affect the load if they do not exceed the stiffness level 4 according to DSTU protection against switching overvoltag es is made...

Page 23: ...e load but the grid will not be able to be in an emergency for a long time and the supply of voltage may stop sooner or later WARNING If the regulator input circuit breaker trips out the regulator pro...

Page 24: ...quant ua January 2022 OUR MERIT SAFE VOLTAGE Automatic voltage regulator one phase...

Reviews: