Chapter 4 — BMC
Sensor
Name
Sensor #
Entity ID
Insta
n
ce
Sensor Type
Event/Reading
Type
Event Triggers
Event
Data
Sensor
Initialization
Sensor
Capabilities
BMC SEL
2Bh
06h
2 Event
Logging
Disabled - 10h
Sensor Specific –
6Fh
2: Log Area Reset/Cleared
4: SELFull
A=0014 D=0000 R=0014
Trigger
Offset
7:0
6:Scan=0
5:Event=1
4:0
3:Hyst=0
2:Type=0
1:Event=1
0:Scan=0
Default=22h
7:Ignore=0
6:Auto=1
5,4:No Hyst=00
3,2:No Thresh=00
1,0: Per Evt=00
Default=40h
DIMM-A0
DIMM-A2 & DIMM-B0
DIMM-B2 & DIMM-C0
DIMM-C2 & DIMM-D0
DIMM-D2 & DIMM-E0
DIMM-E2 & DIMM-F0
DIMM-F2
60h ~
71h
20h
1 -- 18
Memory - 0Ch
Sensor Specific -
6Fh
0:Correctable error (A, R)
1:Uncorrectable error (A, R)
A=0003 D=0000 R=0003
Trigger
Offset
7:0
6:Scan=0
5:Event=1
4:0
3:Hyst=0
2:Type=0
1:Event=1
0:Scan=0
Default=22h
7:Ignore=0
6:Auto=1
5,4:No Hyst=00
3,2:No Thresh=00
1,0:Per Evt=00
Default=40h
98