BIOS
S
ERVER
M
ANAGEMENT
S
CREEN
2-9
BMC firmware
version
Information only. Displays the
BMC firmware version.
IPMI version
Information only. Displays the
IPMI version.
FRB-2 Timer
[
Disabled
]
[Enabled]
Enable or Disable FRB-2 timer
(POST timer)
Not available if FRB2 Timer is dis-
abled.
FRB-2 Timer
timeout
[3 minutes]
[4 minutes]
[5 minutes]
[
6 minutes
]
Enter value Between 3 to 6 min
for FRB-2 Timer Expiration value
Not available if FRB2 Timer is dis-
abled.
FRB-2 Timer Pol-
icy
[Do Nothing]
[
Reset
]
[Power Down]
Configure how the system
should respond if the FRB-2
Timer expires. Not available if
FRB2 Timer is disabled.
Not available if FRB2 Timer is dis-
abled.
OS Watchdog
Timer
[Enabled]
[
Disabled
]
If enabled, starts a BIOS timer
which can only be shut off by
Intel Management Software after
the OS loads. Helps determine
that the OS successfully loaded
or follows the O/S Boot Watch-
dog Timer policy.
OS Wtd Timer
Timeout
[5 minutes]
[
10 minutes
]
[15 minutes]
[20 minutes]
Configure the length of the OS
Boot Watchdog Timer. Not avail-
able if OS Boot Watchdog Timer
is disabled.
Not available if watchdog Timer
is disabled.
OS Wtd Timer
Policy
[Do Nothing]
[
Reset
]
[Power Down]
Configure how the system
should respond if the OS Boot
Watchdog Timer expires. Not
available if OS Boot Watchdog
Timer is disabled.
Not available if watchdog Timer
is disabled.
System Event
Log
Press <
Enter
> to change the SEL
event log configuration.
View FRU infor-
mation
Press <
Enter
> to view FRU infor-
mation.
BMC network
configuration
Configure BMC network parame-
ters
Restore on AC
Power Loss
[Power Off ]
[Power On]
[Last State]
[
No Change
]
System action to take on AC
power loss
Current Restore
on AC Power
Loss
Information only. Displays the
current system action to take on
AC power loss.
Table 6: Server Management Screen Description (Continued)
S
ETUP
I
TEM
O
PTIONS
H
ELP
T
EXT
C