BMC
P
LATFORM
E
VENT
4-4
Platform Event
Platform Event Filter
The BMC implements selectable action on an event or LAN
alerting base on event. By
default, no any PEF entries or actions exist, applications need
to configure it to enable.
The number of Platform Event Filter Table is 40.
The number of Alert Policy Table is 120 and Alert Destina-
tion Table is 30.
Dedicated and Shared NIC)
The policy to match an event to Platform Event Filter Table
entry is IPMI 1.5 standard.
The action support Power Off, Power Reset, Power Cycle
and NMI.
All Platform Event Filter Table is default disabled.
PEF Startup Delay and Last Processed Event tracking is
not supported.
PEF table lookup isn’t correlated to log SEL to SEL
Repository.
Serial Alerting is no support.
BMC Firmware Update
The BMC will allow users to upgrade firmware image on follow-
ing entities:
BMC
All other upgradable entities
The update capability is provided by local and remote inter-
faces.
DOS Recovery Utility
SOCFLASH Utility.
WebUI Update
Remote update can be performed through the remote Web con-
sole.
Summary of Contents for STRATOS S210 Series S210-X12MS
Page 21: ...About the Server Chapter 1 About the Server Chapter 1 ...
Page 37: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Page 78: ...BIOS Chapter 3 BIOS ...
Page 135: ...BMC Chapter 4 BMC Chapter 4 ...
Page 194: ...Jumpers and Connectors Chapter 5 Jumpers and Connectors Chapter 5 ...
Page 197: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Page 201: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Page 210: ...Safety Information Chapter 9 Safety Information Chapter 9 ...