BMC
F
RONT
P
ANEL
U
SER
I
NTERFACE
4-2
LEDs
The following table contains information on Status, ID and
Heartbeat LED's.
The following table contains information on Status LED when
amber blinking.
Table 4-1:
Status LED, ID LED, and Heartbeat LED
LED
S
C
OLOR
S
TATUS
D
ESCRIPTION
Power / Sta-
tus LED
Amber (Status
LED)
Blinking
System Event
(See following Status LED
table.)
Off
Normal status
Green
(Power LED
controlled by
BIOS)
On
Power On
Off
Power Off
ID LED
Blue
Off
Normal status
Blinking
Identify the system with
interval
Solid ON
Identify the system
Heartbeat
LED
Green
Off
BMC is not Ready
Blinking
BMC is Ready
Table 4-2:
Status LED Activity
N
O
.
S
TATUS
LED
A
CTIVITY
D
ESCRIPTION
1.
Temperature
Sensor
Non-critical / critical event asserted
2
Fan Sensors
Non-critical / critical event asserted
3
Voltage Sen-
sors
State asserted
4
Power Supply
State asserted
5.
Processor
Thermal trip
6
Event Logging
Disable
SEL almost full
SEL full
7
Post Error
System firmware error
8
Memory
Correctable EEC error
Uncorrectable ECC error
Correctable ECC error log-
ging limit reached
9.
PCIe Bus
Bus correctable error
Bus uncorrectable error
Bus fatal error
Summary of Contents for STRATOS S210 Series S210-X22RQ
Page 22: ...REVISION HISTORY XXII ...
Page 23: ...About the Server Chapter 1 ...
Page 36: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Page 83: ...BIOS Chapter 3 BIOS Chapter 3 ...
Page 152: ...BMC Chapter 4 BMC Chapter 4 ...
Page 218: ...Mainboard Jumpers and Connectors Chapter 5 ...
Page 223: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Page 228: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Page 238: ...Safety Information Chapter 9 Safety Information Chapter 9 ...