Event Filter Action is a mandatory field and checked by
default, which enable PEF Alert action (read-only).
Select any one of the Power action either Power down,
Power reset or Power cycle from the drop down list
Choose any one of the configured alert policy number
from the drop down list.
5. In the Sensor configuration section,
Select the s type of sensor that will trigger the event fil-
ter action.
In the sensor name field, choose the particular sensor
from the sensor list.
Choose event option to be either All Events or Sensor
Specific Events.
6. Click
Modify
to accept the modification and return to
Event filter list.
7. Click
Reset
to reset the modification done.
8. Click on
Cancel
to cancel the modification and return to
Event filter list.
9. In the Event filter list, to modify a configuration, select the
slot to be modified and click
Modify
.
10.In the Event filter list, click
Delete
to delete the existing fil-
ter.
Alert Policy Tab
This page is used to configure the Alert Policy and LAN destina-
tion. You can add, delete or modify an entry in this page.
PEF Management – Alert Policy
The fields of the PEF Management – Alert Policy Tab are
explained below.
Note:
Alert Policy has to be configured - under
Configuration >
PEF > Alert Policy
.
Summary of Contents for STRATOS S210 Series S210-X2A2J
Page 21: ...SAFETY INFORMATION XXI ...
Page 23: ...About the Server Chapter 1 ...
Page 33: ...Installing Hardware Chapter 2 ...
Page 106: ...BIOS Chapter 3 ...
Page 166: ...BMC Chapter 4 ...
Page 229: ...Jumpers and Connectors Chapter 5 ...
Page 236: ...Rail Kit Assembly Chapter 6 ...
Page 240: ...Troubleshooting Chapter 7 ...
Page 245: ...Installation and Assembly Safety Instructions Chapter 8 ...
Page 249: ...Safety Information Chapter 9 ...
Page 258: ...Regulatory and Compliance Infor mation Chapter 10 ...