Two inch deflection, isolator installation and adjustment
WASHER
("F")
("B")
GROMMET
("G")
("A")
("C")
("F")
("E")
("E")
("E")
1/4 - 3/8 GAP
CL
CL
("C")
EQUIPMENT
("A")
Read the following instructions before beginning
installation:
1. Isolators are shipped fully assembled and are to be
positioned in accordance with the submittal draw-
ings or as otherwise recommended.
2.
Set isolators on floor, housekeeping pad, or sub-
base, ensuring that all isolator centerlines match
the equipment mounting holes. The VMC group
recommends that the isolator base plates (B) are
installed on a level surface. Shim or grout as re-
quired, levelling all isolator base plates to the
same elevation (0.25 of an inch maximum differ
-
ence can be tolerated).
3. Bolt or anchor all isolators to supporting structure
using base plate through holes (C) or weld base
plate to supporting structure with 0.375 in. fillet
weld 2 in. long at 4 in. on center around entire
base plate or as engineered for specific load and
or field conditions.
4. Isolators are shipped to the job site with (2) re-
movable spacer shims (E) between the top plate
and the housing. These shims must be in place
when the equipment is positioned over the isola-
tors.
5. With all shims (E) in place, position equipment on
top of plate (A) of isolator.
6. Bolt equipment securely to top plate of isolator
using a minimum of 2 x 0.625 in. UNC A325
GRADE 5 SAE bolts or weld equipment or brack-
et to the top plate (A) of isolator with a minimum
0.375 in. fillet welds 2 in. long at 3 in. O.C. for a
minimum total weld of 10 in. (All sides of equip-
ment or bracket resting on top plate (A) must be
welded).
7. The adjustment process can only begin after the
equipment or machine is at its full operating
weight.
8.
Back off each of the 4 limit stop lock nuts (F) on
the isolators 0.5 in.
9. Adjust each isolator in sequence by turning spring
adjusting nuts (G) one full clockwise turn at a
time. Repeat this procedure on all isolators, one at
a time. Check the limit stop lock nuts (F) periodi-
cally to ensure that clearance between the washer
and rubber grommet is maintained. Stop adjust-
ment of isolator only when the top plate (A) has
risen just above the shim (E).
10. Remove all spacer shims (E).
11. Fine adjust isolators to level equipment.
12. Adjust all limit stop lock nuts (F) per isolator,
maintaining 0.25 in. to 0.375 in. gap. The limit
stop nuts must be kept at this gap to ensure uni-
form bolt loading during uplift, as is the case
when the equipment is drained.
Figure 43 -
Two inch deflection isolator
Summary of Contents for QTC40160
Page 22: ...Quantech 22 Form QTC4 NM2 Issue date 05 12 2023 This page is intentionally left blank...
Page 94: ...Quantech 94 Form QTC4 NM2 Issue date 05 12 2023 This page is intentionally left blank...
Page 100: ...Quantech 100 Form QTC4 NM2 Issue date 05 12 2023 This page is intentionally left blank...
Page 158: ...Quantech 158 Form QTC4 NM2 Issue date 05 12 2023 This page is intentionally left blank...
Page 187: ...Quantech 187 Form QTC4 NM2 Issue date 05 12 2023 This page is intentionally left blank...