SECTION 2 - PRODUCT DESCRIPTION
FORM QWC4-NM1 (221)
ISSUE DATE: 02/28/2021
2
SEMI-HERMETIC QUANTECH SCREW
COMPRESSORS
The direct-drive, semi-hermetic rotary screw com-
pressor incorporates advanced technology in a rugged
design. The continuous function, microprocessor con-
trolled VSD provides smooth capacity control from
100% down to 20% chiller capacity. State-of-the-art
screw compressor design and manufacturing ensures
optimal efficiencies at all chiller load points. With no
unloading steps or slide valves in the compressor, the
QWC4 variable speed driven compressor has 50%
fewer moving parts than fixed speed compressors
with slide valves. The QWC4 compressor is one of
the most efficient and reliable screw compressors in
the industry.
EVAPORATOR
The evaporator is a shell and tube, hybrid falling film
type heat exchanger. It contains a balance of flooded
and falling film technology to optimize efficiency, min-
imize refrigerant charge, and maintain reliable control.
A specifically designed distribution system provides
uniform refrigerant flow for optimum performance.
CONDENSER
The condenser is a shell and tube type, with a dis-
charge gas baffle to prevent direct high velocity im-
pingement on the tubes. The baffle is also used to
distribute the refrigerant gas flow properly for the
most efficient heat transfer. An integral sub-cooler is
located at the bottom of the condenser shell provid-
ing highly effective liquid refrigerant subcooling to
provide the highest cycle efficiency.
REFRIGERANT CIRCUIT
The QWC4 has one independent refrigerant circuit
per compressor. An electronic expansion valve (EEV),
controlled by the unit panel, accommodates varying
head and load conditions. The condenser shell is ca-
pable of storing the entire system refrigerant charge
during servicing. Optional service valves are available
to facilitate the removal of refrigerant. The sub-cooling
economizer (plate heat exchanger type), controlled by
the unit panel, meters some refrigerant gas to the com-
pressor to reduce energy consumption.
COMPLETE FACTORY PACKAGE
Each unit is shipped as a complete factory package,
completely assembled with all interconnecting refrig-
erant piping and internal wiring and ready for field
installation. Before shipment, each individual chiller
undergoes an extensive testing procedure, ensuring
workmanship is the highest quality and that the initial
start-up is trouble-free.
Before leaving the factory, each refrigerant circuit
is factory pressure tested, evacuated and then fully
charged with R-134a refrigerant and oil. An opera-
tional test is performed with water flowing through the
evaporator and condenser to ensure each circuit func-
tions correctly.
ELECTRICAL
All controls and motor starting equipment necessary
for unit operation are factory wired and function tested.
There are no surprises at start-up; the unit will start up
correctly the first time and every time. The standard
unit is equipped with circuit breaker for electrical con-
nections. The chillers come with a single point power
connection and are supplied with a factory mounted
and wired control transformer that powers all unit con-
trols from the main unit power supply. The transformer
uses scheduled line voltage on the primary side and
provides 115 V / 1 Ø on secondary. All exposed power
wiring is routed through liquid-tight, UV-stabilized,
non-metallic conduit.
VSD Power/Control Panel includes main power con-
nections, VSD contactors, current overloads, and fac-
tory wiring. All display and control features can be ac-
cessed through the keypad and control display access
door, eliminating the need to open the main cabinet
doors.
BUILDING AUTOMATION SYSTEM
CAPABILITIES
The E-Link Gateway provides an economical and ver-
satile connection between Quantech equipment and
open/standard protocols. It efficiently manages the
communication protocols currently used by Quantech
equipment, exposing the data in a consistent, orga-
nized, and defined fashion. A simple switch selection
allows configuration of the required equipment profile
and output protocol, which reduces equipment connec-
tivity startup time.
Summary of Contents for QWC4
Page 14: ...QUANTECH 14 FORM QWC4 NM1 221 ISSUE DATE 02 28 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 64: ...QUANTECH 64 FORM QWC4 NM1 221 ISSUE DATE 02 28 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 82: ...QUANTECH 82 FORM QWC4 NM1 221 ISSUE DATE 02 28 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 130: ...QUANTECH 130 FORM QWC4 NM1 221 ISSUE DATE 02 28 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 146: ...QUANTECH 146 FORM QWC4 NM1 221 ISSUE DATE 02 28 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 152: ...QUANTECH 152 FORM QWC4 NM1 221 ISSUE DATE 02 28 2021 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 155: ...QUANTECH 155 NOTES...