3. Commissioning 

 

1)  Remove the lid and fill the water tank with water (see water level gauge outside). 

 

      Never operate the unit with a liquid level beneath the lowest water level mark      
      

“min”!

 

 
2)  Connect the water pipes, check for possible leaks. 

 

3)  The  unit  is  designed  to  operate  with  a  tank  temperature  control  kit  which  includes  a 

submersible pump and plastic tubes to lead Glycol water through it. The fittings on the lid 
of the  unit  should  be  used  to  connect the  plastic  tubes.  Such kits  are  not  provided  with 
the unit. If used, please connect them according to the instructions of the manufacturer.  

 

4)  Close the lid. 

 

 

            Do not operate the unit when it is open with the lid removed!

 

 

 

5)  Establish the electric network connection (see 1.5 Electrical installation) 

 

6)  Adjust the required temperature on the thermostat (see 5. temperature setting). After    
      reaching the adjusted set-point temperature the unit is ready for operation (see also 1.1     
      safety measures).

 

        
 

3.1 Connection 

Verify that all connections are sealed. No dirt particles may gain access into the pipes and 
the cooling water in the unit.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GLY401

Page 1: ...NICHILLY SB COMPATIBLE 115V WTG Quantor GmbH Europa Allee 53 D 54343 F hren Phone 49 0 6502 999 95 0 Fax 49 0 6502 999 95 75 eMail info quantor technology Homepage www quantor technology GB Attention...

Page 2: ...4 1 6 Service 4 2 Intended use 4 3 Commissioning 5 3 1 Connection 5 3 2 Chart 6 4 Decommissioning 7 5 Temperature setting 7 6 Cleaning of the cooling unit 9 7 Troubleshooting 9 8 Noise emission 10 9 T...

Page 3: ...clean from any dirt fiber etc Make sure to connect the unit to the required supply voltage Protect the unit from moisture no fluids may enter the electric parts Observe the warning and safety informa...

Page 4: ...consulted with the manufacturer The unit may only be stored in a dry dust free environment at temperature of 0 C to 40 C 1 5 Electrical installation All electrical installations are to be carried out...

Page 5: ...used to connect the plastic tubes Such kits are not provided with the unit If used please connect them according to the instructions of the manufacturer 4 Close the lid Do not operate the unit when i...

Page 6: ...omp 1 Water level gauge and tank emptying 4 Thermostatic controller 2 Cover fastener 5 Small pipes for water return flow 3 Connections 3 8 5 Expansion valve 8 Water tank 6 Condenser 9 Evaporator cooli...

Page 7: ...the unit with clear water only without Glycol or remnants of Glycol in the water system Recommended set point temperature for using an ice bank 1 0 C 30 2 F ATTENTION to avoid damage on the unit free...

Page 8: ...water mixture approx 30 propylene glycol Please pay attention that the water bath temperature must not fall below 6 C and must not exceed 30 C Controller activation for a minimum set point down to 6...

Page 9: ...Starting device at the compressor is defect Interference of the compressor interwinding fault Establish main connection plug the unit Fill in water Switch on the Thermostat Change the Thermostat Exch...

Page 10: ...s steel Mobile on wheels 10 Declaration of conformity We WTG Quantor GmbH D 54343 F hren declare in sole responsibility that the cooling units MiniCHILLY 05 MiniCHILLY 09 and MiniCHILLY 17 which this...

Page 11: ...11...

Page 12: ...E D I E N U N G S A N L E I T U N G I N S T R U C T I O N M A N U A L I N S T R U C T I O N S D E S E R V I C E M A N U A L D E I N S T R U C C I O N E S Doc ID 2018 06 SBComp115V www quantor technol...

Reviews:

Related manuals for GLY401