SPECIFICATIONS
9730 Series
Toll Free
(800) 510-6530
Fax
(406) 582-0237
info@quantumcomposers.com
Web
www.QuantumComposers.com
Standard Features
• Up to 4 individual outputs with fully individual programming
and control.
• Up to 6A output per channel.
• Front and rear external trigger inputs.
• Current monitor – The current output from the unit is monitored and a
voltage representation the waveform is presented at a front panel BNC
connector.
• Voltage monitor- The voltage across the load being driven is monitored
and a voltage representation is present at a front panel BNC connector.
*Instantaneous power and total energy may be derived with the aid of
both the current and voltage monitors.
• SAFETY - Keyed front panel fire enable, mechanical and software
interlocks.
• Complete channel and system setup stored in memory. Provides
12 memory storage slots.
• Meets Bruceton and Neyer requirements
• Analog signals depicting current and voltage
Configurations
9732 – 2 Output Channels
9734 – 4 Output Channels
input module - front and rear trigger
INTERNAL RATE GENERATOR
rate
0.01 Hz to 40 KHz
resolution
100
ns
accuracy
20
ns
jitter
10 ns RMS
burst mode
2 to 250 pulses
output
modes
single
pulse,
burst
control modes
internal rate generator, external trigger
EXTERNAL TRIGGER INPUTS
function
generate individual pulses (single shot or burst)
front or rear
selectable between front or rear panel inputs
external trigger rate
Min = 5 X Longest Pulse Width
Max = 200 Seconds
insertion
delay
300
ns
jitter
10
ns
impedance
1K Ω
Slope
rising
or
falling
trigger filter
filters out unwanted “glitch” or “runt” pulses
range
0.02
us
to
1
ms
resolution
0.02
us
trigger level
2-15 V
level threshold
100 mV
RISE TIMES
rising edge - inductive
4 us (1 ohm, 50’ cable, 6 A) varies with load
rising edge - resistive
550 ns (1 ohm, 2” cable, 6 A)varies with load
SLEW RATES:
rising edge - inductive
2 A/us @ 6 A
(varies with load)
1 A/us @ 3 A
0.30 A/us @ 1 A
(1
ohm
and
50’
cable)
falling edge - inductive
-1.60 A /us @ 6 A
(varies with load)
-0.90 A/us @ 3 A
-0.30 A/us @ 1 A
(1
ohm
and
50’
cable)
rising edge - resistive
6.3 A/us @ 6 A
(varies with load)
9.5 A/us @ 3 A
2.2 A/us @ 1 A
(1
ohm
&
2”
cable)
falling edge - resistive
-5.2 A/us @ 6 A
(varies with load)
-4.0 A/us @ 3 A
-1.3 A/us @ 1 A
(1
ohm
&
2”
cable)
control modes
internal rate generator, external trigger
burst mode
2 to 250 pulses
accuracy
20
ns
rate
0.01 Hz to 40 KHz
function
generate individual pulses (single shot or burst)
front or rear
selectable between front or rear panel inputs
external trigger rate
Min = 5 X Longest Pulse Width
Max = 200 Seconds
jitter
10
ns
Slope
rising
or
falling
range
0.02
us
to
1
ms
trigger level
2-15 V
rising edge - inductive
4 us (1 ohm, 50’ cable, 6 A) varies with load
rising edge - inductive
2 A/us @ 6 A
(varies with load)
1 A/us @ 3 A
0.30 A/us @ 1 A
(1
ohm
and
50’
cable)
rising edge - resistive
6.3 A/us @ 6 A
(varies with load)
9.5 A/us @ 3 A
2.2 A/us @ 1 A
(1
ohm
&
2”
cable)