6-123
FMTN
ForMaT New
Classification:
Format editor control
Command Syntax:
FMTN [<name>]
Limits:
<name> = a valid MS-DOS filename
(8 characters minus any extension)
Query Syntax:
None
Description:
The FMTN command initializes the format editing buffer. Sending
this one command is equivalent to sending all of the following
commands:
A S B G 0
G A M A 2 . 2
A S C T 1
G A M C 0
A S G G 1
H R A T 0
A S S G 0 , 1 , 0
H R E S 0
A S S S 0 . 2 8 6
H S I Z 2 8 0
A V P G 0
H S P D 0
A V P S 0 . 0
H S P G 1
A V S B 0 . 0
H S P P 0
A V S S 0 . 7 1 4
H S P W 0
A V S T 0
H T O T 0
X V S G 1 , 1 , 1
S C A N 1
C S P G 1
S S S T 1
C S P P 0
U S I Z 2
D C B M 0
V R E S 0
D S E X 0
V S I Z 2 1 0
D S S T 1
V S P D 0
D V S P 0
V S P G 1
D V S T 0
V S P P 0
E Q U A 0
V S P W 0
E Q U B 0
V T O T 0
This should be the first command sent to the generator when
creating a new format. The command only resets to a known
state. The command does not create a usable format.
Other Required Cmds:
None
Example:
F M T N / / I n i t i a l i z e f o r m a t b u f f e r
Summary of Contents for 801GC, 801GF, 801GX
Page 1: ...Owner s and Programmer s Manual Model 801GC 801GF 801GX Portable Video Signal Generators ...
Page 16: ...xiv Table of Contents Models 801GC 801GF 801GX Rev A Notes ...
Page 17: ...1 1 Features Product Overview Chapter 1 Introduction ...
Page 21: ...2 1 Operating Modes Displays Indicators Knobs Switches Buttons Chapter 2 Basic Operation ...
Page 31: ...3 1 Introduction Format charts Chapter 3 Built In Formats ...
Page 39: ...4 1 Description of the test images and how to use them Chapter 4 Built In Images ...
Page 126: ...5 14 Chapter 5 Making Connections Model 801GC 801GF 801GX Rev A Notes ...
Page 304: ...6 178 Chapter 6 Programming Model 801GC 801GF 801GX Rev A Notes ...
Page 305: ...7 1 Power on Computer Interfacing If all else fails Chapter 7 Troubleshooting ...
Page 346: ...A 6 Appendix A Specifications Model 801GC 801GF 801GX Rev A Notes ...
Page 355: ...Notes ...