Section 2:
Controls/Circuit Protection Devices
There is one main fuse, a 300 ampere ANL
type fuse, shown to the right, located beside
the inverter. There is one spare fuse
included in the spare parts kit. To replace
the fuse, first, be sure the main switch is
turned off, then, using a 9/16” wrench,
remove the two nuts. Lift the fuse out and
place the new one over the studs; reapply
the nuts, being careful to not over-tighten.
Detail of Main Control Panel
Anderson connector for external batteries Voltage/Charging amps meter 220 volt AC
breaker
12 Volt DC
cigarette
lighter-style
outlets
USB charger ports (2) 120 volt AC outlets 220 volt AC outlet
Main Switch; 4 positions available.
Off
position isolates the inverter and control panel from the batteries.
Position #1
is the normal use position in which the unit draws from the internal battery bank.
Position #1&2
is the position used when using an external battery(s), and allows the unit to run
from both the internal battery bank and the external source .
Position #2
is not normally used, and allows the load to be run directly from an external source,
bypassing the internal battery bank.