Owner’s  Manual

                                                      Quantum  Energy  Technologies 

 
Document number: QDC0030PD-16.4                                                                                                Page 17 of 36 

can be quite common – Off Peak tariffs are not recommended for Quantum water heaters. 

2.    Check  that  the  thermal  overload  (on  the  digital  controller)  has  not  been  tripped.  If  so 

press the “Set” button (hold for 6 seconds) to reset it. 

3.    Is the Pressure & Temperature Relief valve discharging too much water? See Section 7a: 

"Pressure & Temperature Relief Valve Running".

 

4.    Do  you  have  the  correct  size  water  heater  for  your  requirements?    Sizing  details  are 

available from your Quantum supplier. 

5.    Is  one  outlet  (such  as  the  shower)  using  more  hot  water  than  you  think?  Carefully 

review  the  family's  hot  water  usage  and  if  necessary check  the  shower  flow  rates  with  a 
bucket and a  watch.  If  it  is  not  possible  to  adjust  water  usage  patterns,  an  inexpensive 
flow  control valve can easily be fitted to the shower outlet. 

 
7c: High Electricity Bills

 

1.    Is  the  Pressure  &  Temperature  Relief  valve  discharging  too  much  water?    See  Section 

7a: 

"Pressure & Temperature Relief Valve Running”.

 

2.    Is one outlet (such as the shower) using more hot water than you think?    See Section  7b: 

"No Hot Water”.

 

3.    Is there a leaking hot water pipe or dripping hot water tap? A small leak can waste a large 

quantity of hot water.

 

4.    Replace faulty tap washers and have your plumber rectify any leaking pipe work.

 

5.    Have any new appliances been installed that might be using the extra power? 

6.    If there are no water leakages around the building and no excessive usage of hot water, yet 

electricity  bills  are  higher  than  normal  (without  any  other  appliance  being  responsible) 
then  it  may  indicate  a  problem  with  the  water  heater.  Contact  your  nearest  Quantum 
distributor or service agent. 

 
 

Section 8: WARRANTY CERTIFICATE

 

8a.  Terms Of Warranty

 

QUANTUM WATER HEATERS are manufactured by Quantum Energy Technologies Pty Ltd. QUANTUM ENERGY 

TECHNOLOGIES PTY LTD (the Company) WARRANTS    “THIS QUANTUM ENERGY SYSTEM” (the unit) 

against faulty workmanship, materials and defects in manufacturing as here in after provided: - 

1.    Storage tank integral with condenser coil: - Warranted for a period of five (5) years from the date of installation 

2.    Refrigeration  pipe  work,  refrigeration  valves,  compressor,  fan  coil  and  motor,  electrical  components  including 

thermostats, digital controller, solenoids, wiring and controls: - warranted for a period of two (2) years from date of 
installation. Plumbing valves supplied with the unit are covered by their respective manufacturers’ warranties. 

3.   Labour,  delivery  and  /  or  transportation:  -  Where  the  Company  considers  it  necessary  to  repair  or  replace  any 

component part covered by the warranty, the consequential labour, delivery and / or transportation services will be 
provided free of charge to the owner within a fifty-kilometre radius from where the unit was purchased. Customers 
outside this area will be subject to freight and traveling charges incurred by the service agent carrying out the work. 
The date and time of the commencement of such warranty work will be at the discretion of the Company. Quantum 
does not  warrant that such repair  work  will  take place  within any particular period. A call out  fee applies  to any 
warranty calls made outside normal QUANTUM business hours. 

The  Company’s  liability  under  this  warranty  shall  be  limited  to  the  free  replacement  or  repair  of  any  defective 
component parts of the unit and shall not cover any consequential loss or damage arising out of any such defect. 

Summary of Contents for 150-08ACW-134

Page 1: ...50 08ACW 134 200 08ACW 134 270 11AC3 134 340 11AC3 134 270 11AC4 134 340 11AC4 134 340 17ACW 134 Split 150 08ASW 134 200 08ASW 134 270 11AS4 134 340 11AS4 134 340 17ASW 134 340TIH 134 with Recommended...

Page 2: ...Relief Valve PTR 3e Expansion Control Valve ECV 3f Cold Water Connection 3g Pressure Reducing Valve 3h Caution Regarding Glass Lining Of Tank 3i Suitability For Installation In Frost Areas 3j Draining...

Page 3: ...essure Temperature Relief Valve Running 7a 1 Continuous Trickle 7a 2 Steady Flow 7b No Hot Water 7c High Electricity Bills Section 8 WARRANTY CERTIFICATE 8a Terms of Warranty 8b Items Not Covered By W...

Page 4: ...CONNECTIONS FOR COMMERCIAL MODELS WARRANTY CARD NOTES Owner s Use 28 28 28 29 30 30 30 30 31 31 31 31 32 33 35 List of Figures Figure 1 Installation Diagram Compact Systems Figure 2 Installation Diag...

Page 5: ...uburb State Territory Postcode Date of Purchase Purchased From Model Serial Number Date of Manufacture Details on Data Plate on water heater 1b Installer s Details Date of Installation Installer s Nam...

Page 6: ...and plumbing connections are completed in the same manner There is also the Split design which can be used to recover heat from a warm area like the roof space or the kitchen The remote fan coil energ...

Page 7: ...metre therefore locating the unit away from bedrooms or living areas is recommended both the owners any neighbors Note All models are equipped with a sacrificial anode accessible through the top cove...

Page 8: ...er supply the ECV should be rated at 150kPa lower than the Pressure Temperature Relief valve PTR It is a State requirement for SA QLD that an ECV be fitted on the cold water supply line between the no...

Page 9: ...In installing single Compact units the fan should point out from or along the wall 2 If the fan has to point towards to the wall the distance between the unit and the wall should be at a minimum of 5...

Page 10: ...4 Page 10 of 36 Figure 2 Installation Diagram Split Systems Power Connection Water Connections PTR Valve 35 32 Front Access 100 mm Min 200 500 mm Wall Note The pipes connected to the water heater s co...

Page 11: ...ng to the local regulations and AS3000 A 10 or 15 amp circuit breaker must be installed at the power supply for the hot water units up to 0 8kW or 1 7kW respectively The power connection rating for Qu...

Page 12: ...ter the air is expelled from its line 4b Water Quality Your Quantum water heater has been manufactured to suit the water conditions of most Australian and New Zealand metropolitan supplies Please note...

Page 13: ...hanism on the relief valve There is a possibility that manually opening the relief valve may allow contamination grit etc to settle in the valve seat causing continuous leakage If the relief valve is...

Page 14: ...nscrew it 6d Service Caution Before Any Work Is Carried Out Before any electrical components are inspected the System MUST be turned off at the power switch hot water circuit breaker Do not touch wiri...

Page 15: ...est distributor or service agent Our website www quantumenergy com au and www quantumenergy co nz also provide an up to date list of Quantum distributors 6f 3 Access Removal Of Sacrificial Anode The a...

Page 16: ...geration Thermostat Servicing Qualified refrigeration technicians only should service the heat pump The information provided in Appendix A Trouble Shooting Guide will provide the necessary information...

Page 17: ...a problem with the water heater Contact your nearest Quantum distributor or service agent Section 8 WARRANTY CERTIFICATE 8a Terms Of Warranty QUANTUM WATER HEATERS are manufactured by Quantum Energy T...

Page 18: ...dition to all other rights and remedies available to the consumer under the Trade Practices Act 1974 as amended and other relevant local laws and shall not be taken as applying to exclude restrict or...

Page 19: ...No responsibility shall be accepted for delays due to Unavailability of parts from suppliers Extreme delays due to unusually high demand for service 8c Before Phoning For Service Please check the fol...

Page 20: ...530 2650 2240 1490 650 1660 315 150 08ASW 134 90 240 1650 1545 975 540 660 125 200 08ASW 134 105 305 1650 1875 1305 540 660 175 270 11AS4 134 120 390 1900 1765 1190 650 986 250 340 11AS4 134 155 495 1...

Page 21: ...eration Connection Power Cable 100 110 50 40 150 A qualified refrigeration technician must install the Split Air model While the plumbing and electrical work is the same as the Compact this unit also...

Page 22: ...Axx the compressor temperature Push again to display bxx evaporator temperature or again for Cxx ambient temperature c During the time delay start period press hold for 3 seconds to force a compresso...

Page 23: ...circuit Auto reset E03 Evaporator temperature sensor open or short circuit Auto reset E04 Compressor overload protection Auto reset the first time manual reset the second time E05 Compressor overheat...

Page 24: ...finishing the adjustment press the SET button again to confirm The screen flashes once to indicate the adjustment has been updated successfully Press the SET button again to enter the next menu or ret...

Page 25: ...r s Manual Quantum Energy Technologies Document number QDC0030PD 16 4 Page 25 of 36 Fig 6 Wiring Diagram 150 200 08ACW 134 270 340 11AC3 134 Fig 7 Wiring Diagram 150 200 08ASW 134 340 17ASW 134 340TIH...

Page 26: ...Owner s Manual Quantum Energy Technologies Document number QDC0030PD 16 4 Page 26 of 36 light Fig8 Wiring Diagram 340 17ACW 134 Fig 9 Fault Indicator 340 17ACW 134 Indicator...

Page 27: ...l Quantum Energy Technologies Document number QDC0030PD 16 4 Page 27 of 36 Fig 10 Wiring Diagram with Timer 150 200 08ACW 134 270 340 11AC4 134 Fig 11 Wiring Diagram with Timer 150 200 08ASW 134 270 3...

Page 28: ...to start Check the voltage Hit the compressor gently by a wood hammer Replace compressor 5 Thermal cut out TCO on digital controller tripped off No power to compressor after thermal cut out TCO If TC...

Page 29: ...or replace compressor if it is faulty I Make the sensor contact the tank well II Replace faulty water thermostat digital controller III If restriction is not removable replace blocked part IV Replace...

Page 30: ...er a very wide range of evaporating and condensing temperatures To identify undercharge or overcharge of refrigerant gas in the system three parameters need to be checked 1 Current Draw 2 System Press...

Page 31: ...inuous liquid through sight glass Assuming TX valve is functioning normally evaporator tends to flood head pressure tends to be high current draw is high and compressor is noisy A 11 Technical Data Fo...

Page 32: ...alve 1 Expansion Control Valve 2 Item Description Cold Water In DN20 Description Item Hot Water Cold Water TIPS 1 If the water supply pressure beyonds 800Kpa This device must be installed 2 It is reco...

Page 33: ...ration Split System Last Name Phone Work Phone Mobile P C Warranty Registered Office Use Only Date Manufactured Install Type New Replace Date Installed Old System Type Tank Position External Internal...

Page 34: ...Owner s Manual Quantum Energy Technologies Document number QDC0030PD 16 4 Page 34 of 36 BLANK PAGE...

Page 35: ...Owner s Manual Quantum Energy Technologies Document number QDC0030PD 16 4 Page 35 of 36 NOTES Owner s Use...

Page 36: ...LIA A B N 88 095 959 327 Phone 61 2 9699 7444 Fax 61 2 9699 5386 18b Tarndale Grove Albany Auckland New Zealand Phone 64 9 443 6354 Fax 64 9 443 6356 NOTE Every care has been taken to ensure the accur...

Reviews: