background image

Quantum Scalar i500: Ethernet Expansion Blade Installation

6-68141-01 Rev A

April 2014

Installing the Ethernet Expansion Blade

5

You must do this BEFORE placing the Ethernet Expansion blade into the 

library. 

6

Prepare the library for Ethernet Expansion blade installation. The Ethernet 

Expansion blade must be installed in the lower left bay of an expansion 

module. 

• In some cases, installing the Ethernet Expansion Blade may require 

removal or relocation of an FC I/O blade and its accompanying fan 

blade. 

• Remove the cover plate covering the two bottom left slots. To remove 

the cover plate, unscrew the two captive thumbscrews securing the 

cover plate and pull outward on the plate. Save the cover plate in case 

you need to use it later.

7

Remove the new Ethernet Expansion blade from the protective anti-static 

bag.

8

Press up and out to open the latch hooks on each side of the blade. Hold the 

Ethernet Expansion blade upright with the latch hooks on the left side, and 

the status LEDs at the bottom (see 

Figure 1

 on page 2).

9

Carefully align the Ethernet Expansion blade with the guide slots in the bay.

Caution:

Forcing the blade into the bay can cause the pins to bend. 

10

Evenly apply pressure to both sides of the blade and slide it into the 

expansion module until the latch hooks begin to move toward the middle of 

the blade. Push the latch hooks toward the middle of the blade and into the 

locked position. You will feel the blade pins connect with the expansion 

module’s backplane as the blade locks into place.
The status LEDs on the Ethernet Expansion blade should be as follows: The 

blue LED should blink once every 10 seconds, indicating the blade is 

powered on. The green LED should blink once per second, indicating the 

blade’s processor is working normally. The amber LED should be off. If the 

LEDs are not blinking properly, reseat the blade.

Caution:

Be sure the cover plate is installed over the empty bay to the 

right of the Ethernet Expansion blade. If the cover plate next to 

an Ethernet Expansion blade is not installed, Ethernet 

Expansion blade temperature errors will occur.

11

Cable the Ethernet Expansion blade (see 

Cabling the Ethernet Expansion 

Blade

 on page 6).

12

Power on the library.

13

Verify that the Ethernet Expansion blade is in the “Ready” state using one of 

the following methods:

• Check the LEDs on the Ethernet Expansion blade. 

The green LED should blink once per second, the blue LED should blink 

once every 10 seconds, and the amber LED should be off.

Summary of Contents for Scalar i500

Page 1: ...its affiliates in the United States and or other countries All other trademarks are the property of their respective owners Quantum specifications are subject to change Quantum Scalar i500 Ethernet E...

Page 2: ...thernet Expansion Blade LTO 5 and LTO 6 FC tape drives enable you to use tape drive Ethernet connectivity for FIPS certified key exchanges tape drive log collection tape drive firmware updates and tap...

Page 3: ...an 5U it is recommended that all HP LTO 5 FC or HP LTO 6 FC tape drives be connected to an Ethernet Expansion blade The Ethernet Expansion blade is not in the data path and does not affect tape drive...

Page 4: ...to connect the LCB to the expansion module in which the Ethernet Expansion blade is installed Tools Required None Instructions 1 Upgrade library firmware to version 600G or later 2 Upgrade tape drive...

Page 5: ...bay can cause the pins to bend 10 Evenly apply pressure to both sides of the blade and slide it into the expansion module until the latch hooks begin to move toward the middle of the blade Push the l...

Page 6: ...pansion blade to be sure it says Ready see Figure 2 on page 6 14 Save the library configuration a From the Web client select Tools Save Restore Configuration b Select Save System Configuration and cli...

Page 7: ...the Ethernet Expansion blade is installed There are two ports marked UPPER and LOWER Since the Ethernet Expansion blade must be installed in the lower bay of the expansion module you must use the port...