121
Connecting LTO-5 Drives to Ethernet Expansion Blades
Use these instructions to install the Ethernet Expansion blade cables that connect the LTO-5 drives to the
Ethernet Expansion blades.
Required tools: ESD strap
Use Quantum provided cables: FRU ID 834
1
Open the service door of the control module or expansion module.
2
Attach the ESD strap to your wrist and to an unpainted surface inside the door.
3
Remove and discard the protective covers from the Ethernet connector on the tape drives.
4
Remove and discard the protective covers from the ports on the Ethernet Expansion blades.
5
Carefully unwrap the EEB cables.
6
Connect the EEB cable to ETH 1 on the EEB that is installed in bay 7 of the I/O management unit. See
on page 119 for information about the cable connection requirements.
Note
• See
on page 119 to see the correct location where the EEB cables
will be connected.
• The goal when installing the EEB cables is to keep the cables out of the way
of the other components in the control module or expansion module. Use the
cable keepers and Velcro straps to accomplish this.
• A maximum of six LTO-5 drives can be connected to one Ethernet expansion
blade.
port 1 on the
EEB in
in bay 7
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...