138
Installing Cartridges
Barcode Requirements
Cartridges must have an external barcode label that is machine-readable to identify the volume serial
number. A barcode must use only uppercase letters A to Z and/or numeric values 0 to 9. The library supports
Code 39 (3 of 9) type barcode labels.
For LTO media barcodes, the library dynamically supports 1 to 14 characters for volume serial number plus
a two-character media type identifier. See the image below for an example of a supported LTO barcode
label.
For SDLT I media barcodes, the library dynamically supports 1 to 6 characters for volume serial number
plus a one-character media type identifier. The image below is an example of a supported SDLT I barcode
label.
For SDLT II media barcodes, the library dynamically supports 1 to 6 characters for volume serial number
plus a one-character media type identifier. The image below is an example of a supported SDLT II barcode
label.
For DLT-S4 media barcodes, the library dynamically supports 1 to 6 characters for volume serial number
plus a one-character or two-character media type identifier. The media identifier should be either “4”.
Quantum-supplied barcode labels will provide the best results. Barcode labels from other sources can be
used, but they must meet the following requirements:
•
ANSI MH10.8M-1983 Standard
•
Number of digits: 6+1 (DLT) or 6+2 (LTO)
•
Background reflection: greater than 25 percent
•
Print contrast: greater than 75 percent
•
Ratio: greater than 2.2
•
Module: >= .254 mm
•
Print tolerance: ±57 mm
two character media
identifier (L1, L2, L3, LT, L4, LU, L5, LV)
character media identifier
must be an “S”
character media identifier
must be a “2”
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...