Scalar i2000 Installation Guide
281
Adding a 72-slot I/E Station to an Expansion Module
This section describes how to upgrade an expansion module to include an access door with a 72-slot I/E
station. The first seven expansion modules can contain 72-slot I/E stations.
Required tools: #2 Phillips screwdriver, 2.5 mm hex wrench, 3 mm hex wrench, wire cutters (for plastic ties),
foot jack, M4x10 screws, ESD strap
1
You must export all media from the access door being replaced.
a. Log into the Library Management Console (LMC).
b. Click
Operations
→
Export.
2
Before removing any magazines in the access door of the expansion module you are upgrading,
determine if the magazines are used in any partitions.
3
If the
Automatic Teach
mode is being used, disable it to perform this upgrade procedure.
4
Remove the magazines in the access door from each partition(s) using the following procedure:
a. Click
Physical
on the
View
menu.
b. Click
Setup
→
Partitions
→
Configure.
The
Partitions
dialog box is displayed.
c. Select the partition that include the affected magazines and click
Modify.
d. Return the affected magazines to the physical pool.
e. Repeat Steps a through d for each partition associated with the access door you are upgrading.
5
Shut down the library.
For more information, see
6
Open the service door of the expansion module that you are upgrading.
Note
Make certain the firmware installed on the library system is the required version
for the 72-slot I/E station functionality. Check Quantum site:
for the lasted firmware information.
CAUTION
All partition elements associated to this upgrade procedure must be
modified before proceeding with this procedure.
Prior to modifying any partitions, you must understand your
configuration changes and the potentially disruptive effects those
changes can have on the host application(s).
Care must be taken whenever you add or delete partition elements,
which includes drives, storage magazines, and I/E station magazines.
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...