308
Installation Testing and Verification
4
Log onto the LMC as a service user.
5
Verify that the LMC is displayed and there are no yellow or red sub-system statuses. If there are yellow
or red statuses, see the
Scalar i2000/i6000 Maintenance Guide
for corrective procedures.
6
For each partition, verify that all drives are online by performing the following:
a. From the LMC, select the partition using the view menu.
b. Click
Monitor
→
Drives
and verify all expected drives are available.
7
From the LMC, click
Tools
→
Teach
to perform a configuration and a calibration on the library.
The
Teach
dialog box appears. The default choice is
Configure
.
8
Click
Start
.
Once the teach is completed, a message appears in the
Results
field, for example, “Command
Completed.”
9
Select
Configure
and click
Start
.
During the calibration teach process, the picker moves to the home position, which is X-Y coordinate
position 0,0. It then moves to a magazine at the top and a magazine at the bottom on each side of each
module, and stores those positions in coordinates relative to the 0,0 position. Teach results appear in
the
Results
area when the process completes. If the calibration teach process completes successfully,
the dialog box closes automatically.
Once you have verified the hardware using this procedure, go to the
Installation Verification Test Overview
on page 309 and proceed with those instructions.
If hardware verification indicates problems, consult the troubleshooting procedures in the
Scalar i2000/
i6000 Maintenance Guide
.
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...