Scalar i6000 Installation Guide
319
Boundary/Accessibility
The boundary/accessibility graphical report shows the results for tests of the accessor while performing get,
put, and scan functions for all tape magazines and drive sleds. (This tests whether magazines and sleds
are within the maximum allowable movement range of the accessor.)
•
If the graphical report shows a failed result for one or more tape magazines, make sure the
magazines at the location of the failure are installed properly and that the calibration targets are
correctly snapped on to the magazines.
•
If the graphical report shows a failed result for the I/E station, make sure the I/E station and front
door are completely shut.
•
If running the test again still generates failed results, realign the middle X-axis rail and check the
alignment of the top and bottom X-axis rails at the location of the failure.