Scalar i6000 Installation Guide
41
Attaching the X-Axis Rails
Attaching and Aligning the Upper and Lower X-Axis Rails
Repeat the following procedure for each additional expansion module, starting with the first new expansion
module and working to the right.
Required tools: 2.5 mm hex wrench
1
Attach the upper X-axis rail as follows:
a. Use the 2.5 mm hex screws to attach the upper X-axis rail loosely.
b. Push the rail to the left and align it front to back with the previous rail so that the joint is smooth.
c. Tighten each screw on the rail beginning at the left end. Do not tighten the screw that is on the
next rail at the junction between the current module and the module to the right.
Note
The X-axis rails are shipped in a package secured in the back of the expansion
module with the cable management ties. Remove the packages and unpack
them in a convenient location before beginning the following procedures.
Note
For expansion modules in positions 9 through 12, the X-axis upper and lower
rails contain longer slots. Check for the rail identification hole which signifies
the replacement X-axis upper or lower rail.
2.5 mm hex screws
2.5 mm hex screw
attached to module on left
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...