Scalar i6000 Installation Guide
67
4
Route the W1 and W2 cables from the new expansion module through the opening in the left bulkhead
of the control module or last expansion module in the existing configuration.
5
Connect the W1 ribbon cable to the J2 connection on the LBX board on the control module or last
expansion module in the existing configuration.
This connects the J1 connection on the LBX board in the new expansion module to the J2 connection
on the LBX board in the control module or last expansion module in the existing configuration.
Note
The LBX board has three versions and the terminator has two versions. For
more information, see
page 349. Make certain you have the correct version LBX based on the
library configuration you are installing.
route the W1 and W2 cables
through opening in the left
bulkhead
LBX board on
expansion module
LBX board on
control module or
W1 cable
J2
J1
J2
J17
J1
expansion module
(large ribbon cable)
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...