Scalar i6000 Installation Guide
3
Authorized persons can access the library only when one or more of the following conditions are true:
•
The library has been taken offline and the
Robotics Enabled
button on the library’s indicator panel
has been turned off.
•
The access door has been opened.
•
The
Power
button on the Library’s indicator panel has been turned off.
•
The AC line cord has been disconnected from the main power source.
Performing Mechanical Maintenance
Observe the following safety guidelines while performing maintenance on the library.
General Guidelines
Before you begin performing maintenance on the library, perform the following tasks:
•
Locate escape routes and emergency exits, and clear them of obstacles.
•
Identify a safe location for library components and other parts that you will remove from the library.
Unauthorized persons should not have access to this location.
•
Have a plan to keep components and equipment clean during work. Maintaining a clean working
environment promotes safety.
Clothing must be in compliance with the following safety guidelines:
•
Clothing must not have metal fasteners.
•
Clothing must be close-fitting so that it cannot be caught in moving machine parts.
•
Long sleeves must be buttoned up or rolled up.
•
Scarves must be removed or the ends must be tucked into other clothing.
•
Long hair must be fully covered.
•
Remove watches, rings, jewelry, badges, and other items that could get caught in or damage
equipment.
Wear safety glasses when you do any of the following tasks:
•
Use a safety drill.
•
Work on springs, retaining rings, and so forth.
•
Solder or work on cables.
•
Clean with chemical agents.
•
Perform any other work that could endanger the eyes.
Wear safety shoes when handling heavy components.
Before you begin work and after you finish, be careful to remove or reinstall all safety provisions as
appropriate (covers, hazard alert messages, warning signs, grounding wires, and so forth).
WARNING
THE AC POWER CORD MUST BE INSTALLED NEAR THE LIBRARY
AND MUST BE EASILY ACCESSIBLE AT ALL TIMES.
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...