Appendix B Fault Symptom Code (FSC) Dictionary
Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide
115
2007
FSC_DRIVE_TIMEOUT_7
Drive time out waiting
for status (drive 7)
Drive
100%
2008
FSC_DRIVE_TIMEOUT_8
Drive time out waiting
for status (drive 8)
Drive
100%
2009
FSC_DRIVE_OLD_
SYSTEM_BOARD
Requires newer
version of system
board
System
100%
200A
FSC_DRIVE_NOT_
PRESENT_1
Drive caddy not
present (drive 1)
Drive
100%
200B
FSC_DRIVE_NOT_
PRESENT_2
Drive caddy not
present (drive 2)
Drive
100%
200C
FSC_DRIVE_NOT_
PRESENT_3
Drive caddy not
present (drive 3)
Drive
100%
200D
FSC_DRIVE_NOT_
PRESENT_4
Drive caddy not
present (drive 4)
Drive
100%
200E
FSC_DRIVE_NOT_
PRESENT_5
Drive caddy not
present (drive 5)
Drive
100%
200F
FSC_DRIVE_NOT_
PRESENT_6
Drive caddy not
present (drive 6)
Drive
100%
2010
FSC_DRIVE_NOT_
PRESENT_7
Drive caddy not
present (drive 7)
Drive
100%
2011
FSC_DRIVE_NOT_
PRESENT_8
Drive caddy not
present (drive 8)
Drive
100%
2012
FSC_INVALID_STUFF_
BYTE_1
Invalid byte received
from drive 1
Drive
100%
2013
FSC_INVALID_STUFF_
BYTE_2
Invalid byte received
from drive 2
Drive
100%
2014
FSC_INVALID_STUFF_
BYTE_3
Invalid byte received
from drive 3
Drive
100%
FSC
Name
Description
FRU Name
Confidence %
Summary of Contents for Sun StorEdge L100
Page 10: ...Figures x Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library User s Guide...
Page 12: ...Tables xii Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library User s Guide...
Page 192: ...Index 176 Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library User s Guide...