Product Manual

Model 9113-1-X

Ethernet Bridge II

for Ultra 3000 Servo

Quartech Corporation

15923 Angelo Drive

Macomb Township, Michigan 48042-4050

Phone:  (586) 781-0373   FAX: (586) 781-0378

   www.QuartechCorp.com

PM9113-1-X Revision 0

The product described in this document can have a variety of uses, the user and those responsible for applying this
equipment must satisfy themselves as to the acceptability of each application and the use of the unit.  Under no
circumstances  will  QUARTECH  CORPORATION  be  responsible  or  liable  for  any  damage,  including  indirect  or
consequential losses resulting from the use, misuse, or application of the unit.

The text, illustrations, charts, and examples included in this document are intended solely to help explain applications
of  the  product.    Due  to  the  many  variables  associated  with  specific  uses  or  applications,  QUARTECH
CORPORATION  cannot  assume  responsibility  or  liability  for  actual  use  based  upon  the  data  provided  in  this
document.

No  patent  liability  is  assumed  by  QUARTECH  CORPORATION  with  respect  to  the  use  of  circuits,  information,
equipment, or software described in this document.

This document is subject to change without notice.

PM 9113-1-X  R evision 0

Summary of Contents for 9113-1 Series

Page 1: ...be responsible or liable for any damage including indirect or consequential losses resulting from the use misuse or application of the unit The text illustrations charts and examplesincluded in thisdo...

Page 2: ...hernet network when used in conjunction with the Quartech Ethernet Gateway program The Ethernet Gateway program creates a virtual serial port that Ultraware will connect to Your computer does not need...

Page 3: ...cations that require understanding Once a session is established between the 9113 and PLC it can remain indefinitely providing both devices remain wired powered and active Once a session is establishe...

Page 4: ...must match the node set in the 9113 The 9113 is configured by the factory to access Ultra node zero which is the default for a new Ultra 3000 drive The node used by the 9113 can be modified using the...

Page 5: ...nd a hub or switche Crossover cables are used to connect two devices directly without a hub or switch Odd numbered pins are always striped even numbered pins are always solid colored The solid brown w...

Page 6: ...its No Parity One Stop Bit 2182 Cable 9113 to 9120 Two Port Multiplexer 9 Pin Female D Type Specifications Electrical 24 VDC 5 200 ma Temperature 0Ec to 60Ec Operational 20Ec to 70Ec Storage Humidity...

Page 7: ...is pushed down toward the product label Currently switches one and three are not implemented The operation of the 9113 is controlled by switch two and four Do not change switch settings while power is...

Page 8: ...ccurs with the Ultra 3000 and red when a response is not received from the Ultra 3000 A response failure will also cause the Fault LED to light and a fault to be logged into the internal Fault Registe...

Page 9: ...is detected the Mode LED will begin flashing red Firmware update always uses DHCP mode Refer to the Firmware Update topic for a description of the subsequent LED activity you can expect to see Interna...

Page 10: ...unting and dismounting To mount the 9113 tilt it forward and hook the clip to the top of the DIN rail Rotate downward until the clip snaps onto the bottom of the DIN rail EN500 22 35 DIN Rail To remov...

Page 11: ...d in conjunction with the Quartech Ethernet Gateway program The Ethernet Gateway program creates a virtual serial port that Ultraware will connect to Your computer does not need to have an actual seri...