background image

>> I recommend setting 70-100mA, for different sensors 
differently, the higher the value, the greater the influence of 
soil on the device, that is, the device is more difficult to cope 
with the response of the soil, if you wind too much current, 
the device can see through the air a half meter -WOW , and 10 
cm into the earth is sad, so that this does not happen, you 
need to intelligently regulate the current in TX, for “weak” 
soils you can 100, and higher, for example, in sandy soil, and 
for chernozem 60-85 mA for large sensors , and for smaller 
sensors, a little more is possible. 

FILTER menu item - SOUND FILTER SETTING 

Ground filter - Suppression of the effect of mineralization of 
the soil allows you to reduce the effect of soil on the input of 
the device, slightly increase the depth of the search, and also 
helps to configure the detector for the best scanning speed by 
the search coil of soil for optimal operation. A decrease in soil 
filtration when searching on low-mineralized soil increases 
the detection depth, however, on highly mineralized soil the 
depth will be small. By adjusting the level of soil filtration, You 
can optimize the search for local soil conditions, as well as the 
scanning speed of the search coil of soil. Lower filters allow 
slower scanning speeds by the soil coil. The choice of higher 
levels of filtration gives the possibility of a higher scanning 
speed by the search coil of soil. Quasar-AWP allows you to 
select five combinations of digital filter configuration. It can 
take the following values: 

• Very slo

w - very slow 

Summary of Contents for ARM

Page 1: ...QUASAR user guide...

Page 2: ...f the device 3 OK button enter button for the soil balance menu 4 Left button backlight on off button 5 Button 6 Right button pinpoint call button 7 Cancel button and button to enter the device menu 8...

Page 3: ...ly replaced by the value of the soil balance in the format 0 0 and the value of the current value in the TX in the format 00 mA the value of the supply voltage is displayed in the format 0 0V In the o...

Page 4: ...ttom line is the value of the current angle of the soil response in degrees The manual angle can be changed using the Left and Right buttons the step is 0 1 degrees Raising and lowering the sensor sho...

Page 5: ...he finer or deeper the target the quieter the sound of the target The larger the target or the less its depth the louder the sound The range of change is 1 7 The buttons Left and Right decrease and in...

Page 6: ...bove 41 in high tone Scheme 3 Goals below 90 are voiced in low tone above 90 in high tone Threshold Thrashhold Background sound in the absence of a target under the sensor voiceover of clean soil Off...

Page 7: ...frequency transmitter frequency It is in the standard range of 70 0 MHz 108 0 MHz It is necessary to choose a free frequency so as not to listen to coin signals on the chanson fm wave It should also b...

Page 8: ...he Right and Left buttons OK exit with saving the result Esc exit without saving When powered by two Li ION batteries connected in series set the value to 6 0V Ferrite calibr ferrite calibration Allow...

Page 9: ...ferrite setting is the key to the correct operation of the device Values need to be adjusted manually a few points for example auto tuning set the value to 30 save the settings exit the operating mode...

Page 10: ...er in the second line B Balance D Desired balance N No compensator Desired balance value of the desired sensor balance level The amplitude and phase value are set to which the auto compensator needs t...

Page 11: ...y saved settings from the profile Menu item BACKLIGHT LEVEL SCREEN BACKLIGHT LEVEL Backlight Setting the brightness level of the backlight 0 off 100 the highest brightness Change the value with the bu...

Page 12: ...the soil allows you to reduce the effect of soil on the input of the device slightly increase the depth of the search and also helps to configure the detector for the best scanning speed by the searc...

Page 13: ...level from the target bottom right alternating values current in the sensor in mA ground balance and battery voltage in V Signograph is the same as the previous menu item only without VDI value VDI is...

Page 14: ...memorize the mask you must press the OK button when exiting by Esc changes are not remembered Checkers displays a sector that will not be voiced SPEED OF GEB GROUND ADJUSTMENT SPEED Autotrack speed s...

Page 15: ...FAST fast To memorize a value it is necessary to press the OK button when exiting via Esc changes are not remembered...

Reviews: