>> I recommend setting 70-100mA, for different sensors
differently, the higher the value, the greater the influence of
soil on the device, that is, the device is more difficult to cope
with the response of the soil, if you wind too much current,
the device can see through the air a half meter -WOW , and 10
cm into the earth is sad, so that this does not happen, you
need to intelligently regulate the current in TX, for “weak”
soils you can 100, and higher, for example, in sandy soil, and
for chernozem 60-85 mA for large sensors , and for smaller
sensors, a little more is possible.
FILTER menu item - SOUND FILTER SETTING
Ground filter - Suppression of the effect of mineralization of
the soil allows you to reduce the effect of soil on the input of
the device, slightly increase the depth of the search, and also
helps to configure the detector for the best scanning speed by
the search coil of soil for optimal operation. A decrease in soil
filtration when searching on low-mineralized soil increases
the detection depth, however, on highly mineralized soil the
depth will be small. By adjusting the level of soil filtration, You
can optimize the search for local soil conditions, as well as the
scanning speed of the search coil of soil. Lower filters allow
slower scanning speeds by the soil coil. The choice of higher
levels of filtration gives the possibility of a higher scanning
speed by the search coil of soil. Quasar-AWP allows you to
select five combinations of digital filter configuration. It can
take the following values:
• Very slo
w - very slow
Summary of Contents for ARM