3
rd
Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
118
Quasonix, Inc.
For example, suppose a conical scan system with no undesired low-frequency AM has a scan rate of 30 Hz. This
system has a recommended AGC Time Constant of 1000 / 30 = 33.3 ms, and an AM Bandwidth of 5 * 30 = 150 Hz,
with AGC Compensation OFF.
The AGC Time Constant should
never
be set lower than recommended. Setting the AGC Time Constant higher is
unlikely to affect performance, though it may degrade performance if vehicle dynamics cause relatively rapid
changes in received signal strength.
The AM Bandwidth may be set lower to reduce noise on the AM signal, or higher to reduce delay on the AM signal.
At the recommended settings, AM phase delay is approximately 30 degrees for typical conical scan and e-scan scan
rates.
If AGC Compensation is enabled, the AGC Time Constant and AM Bandwidth should both be set only as indicated
in Table 8.