3
rd
Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
125
Quasonix, Inc.
14 Appendix D
– Factory Reset Values
When a reset command is activated, the frequency defaults to the lowest valid frequency for the lowest authorized
band on the unit. The reset priority is:
1.
PCM/FM
2.
SOQPSK
3.
Multi-h CPM
4.
QPSK
5.
STC
Reset values for each mode are listed in the following tables.
The default Frequency is 2200.000 MHz.
Table 9: PCM/FM Factory Reset Values
Parameter
Reset State
Parameter
Reset State
Bit Rate
1
Phase Noise Compensation
Off
Combiner (if available)
Off
Muting Timeout
1000
Clock Polarity
Normal
Output Muting
Off
Data Polarity
Normal
Downconvert Antenna
Disabled
Equalizer (if available)
Off
AGC Polarity
+ (Positive)
DQ Encapsulation (if available)
Disabled
AGC Scale
10
Derandomizer
Disabled
AGC Time Constant
100
Differential Decoder
N/A
AGC Zero Mode
Manual
Modulation Scaling
Acquire
AM Bandwidth
100
Modulation Persist
Off
AM Polarity
Normal
IF Filter
Auto
AM Scale
1
Video De-emphasis
Off
AGC Compensation
Enabled