The Channel B Output options, shown in Figure 96, select what signals appear on the Channel B clock/data outputs:
DQE, No DQE, or Test Data.
•
DQE – Selecting DQE enables encapsulation of data on Channel B; if DQ Encapsulation is enabled
(checked) on the Configuration Basic Settings window, the output is encapsulated, otherwise it is not
•
No DQE – Selecting No DQE bypasses data quality encapsulation
•
Test Data – Selecting Test Data causes the output of the Data Generator to display on Channel B clock and
data
Figure 96: Output Controls, Clock/Data Output Channel B
5.4.15 Test Utilities
The Test Utilities selections, accessed via the Advanced Menu, as shown in Figure 97, provide access to the
following options:
•
Noise Generator
•
Data Generator
•
BERT