Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
81
Quasonix, Inc.
Figure 118: Monitor Screen, Signal Strength Not Grey
– AGC Zero Value Displayed
5.4.16.1 RSSI Display
The RSSI display has two modes depending on the option selected in the RSSI Display drop down menu, shown in
Figure 116.
If “Absolute” was the RSSI Display selection for the channel, the actual signal strength is displayed.
If “Relative” was selected, the RSSI displayed is relative to AGC Zero. The following bullets apply to RSSI
Relative:
•
A value of zero indicates no input signal
•
A value above zero indicates how strong the signal is above no input
•
“*** dBm” displayed (Figure 21) indicates AGC is not zeroed and the value is invalid
•
A small “r” displayed next to the Signal Strength label indicates AGC Zero Relative was selected