Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
33
Quasonix, Inc.
Figure 33: Monitor PSD (Spectrum) Only
Figure 34: Monitor Combiner Display Only
5.2.5
Client Level Update Rate
Users may override the receiver level update rate temporarily. The Update Rate buttons at the bottom of the Monitor
screen are used to change in increments between low, medium, and high. The user may press the Stop button to
temporarily pause the screen transmission. This has the effect of taking a snapshot in time (freezing the page) and is
useful to more closely evaluate details, such as a spectrum curve. Network bandwidth usage is roughly halved as
you progress through each setting from High to Low. High is the as-shipped default setting. The receiver continues
normal operation if the Monitor screen is temporarily stopped.