field, as shown in Figure 82. Type the desired scale index in the field or use the up/down scroll arrows to change the
value. The valid modulation scale index range is 0.350 to 8.000.
If the held index number is to be retained following a power-off cycle of the rack, then turn on Mod Persist from the
Advanced PCM/FM Settings screen. Refer to section 5.4.12.2, Modulation Persistence.
Figure 81: Advanced PCMFM Settings Window, Modulation Scale Index Current Value, Read Only
Figure 82: Mod Index Scaling Mode/Hold, Modulation Scale Index with Edit Field
To clear any held modulation scale index number, go to the Main Menu and toggle the Mod Scaling option back to
Tracking. After Mod Scaling is set to Tracking, the modulation index follows the receiver’s present estimate of the
mod index.
5.4.12.4 Phase Noise Compensation
The Phase Noise Compensation (PNC) option is used to set the Phase Noise Compensation value to On, Off, or
Auto. Refer to Appendix D in section 12 for detailed information about PNC.
Figure 83: Advanced PCMFM Settings Window, Phase Noise Compensation Drop Down Menu