3.2 Thermal
The storage temperature of the QTrack
™
Antenna System is rated for -40°C to +71°C, while the operating
temperature is rated for -30°C to +55°C. It is recommended that the unit be kept in a temperature controlled
environment to minimize the risk of operating (or storing) outside the ranges specified.
The 2U Controller features cooling vents on the back of its aluminum chassis. These vents must be kept entirely
unobstructed in order to allow for maximum airflow through the system. Whenever feasible, it is helpful to leave an
open rack space above and below the 2U Controller for additional heat dissipation.
3.3 Electrical
Two USB ports are located on the front panel along with the power switch, as shown in Figure 6. All 2U Controller
electrical connections are located on the rear panel, as shown in Figure 7.
Figure 6: 2U Front Panel