background image

Older Versions of Card and Socket Services:

Some versions of Card and Socket Services dated before 1993 do not support general purpose
I/O cards.  If after careful installation of the Client Driver the DSP-200/300 does not configure or
operate properly, an updated version of Card and Socket Services may be required.  Card and
Socket Services software is available from Quatech.

2.2 DSP-200/300 Enabler for DOS

For systems that are not operating PCMCIA Card and Socket Services software, the 
DSP-200/300 DOS Enabler may be used to enable and configure the adapter.  This Enabler,
DSP230EN.EXE, will operate on any DOS system using an Intel 82365SL or PCIC compatible
PCMCIA host adapter including the Cirrus Logic CL-PD6710 /6720, the VLSI VL82C146, and
the Vadem VG-365 among others.

IMPORTANT:

In order to use the DSP-200/300 Enabler for DOS, the system
MUST NOT be configured with Card and Socket Services
software.  If a Card and Socket Services software is installed, the 
DSP-200/300 Enabler may interfere with its operation and with the
device(s) it controls.

The DSP-200/300 Enabler does not support automatic configuration of adapters upon insertion,
more commonly referred to as "Hot Swapping".  This means the adapter must be installed in one
of the system's PCMCIA sockets before executing DSP230EN.EXE.  If more than one adapter is
installed in a system, the Enabler must be executed separately for each adapter.  Furthermore,
DSP230EN.EXE should be executed to release the resources used by the adapter before it is
removed from the PCMCIA socket.  Since PCMCIA adapters do not retain their configuration
after removal, any adapter that is removed from the system must be reconfigured with the
Enabler after re-inserting it into a PCMCIA socket.

IMPORTANT:

The Enabler requires a region of high DOS memory when configuring
a DSP-200/300. This region is 1000H bytes (4KB) long and by default
begins at address D0000H (the default address may be changed using
the "W" option).  If a memory manager such as EMM386, QEMM, or
386Max is installed on the system, this region of DOS memory must
be excluded from the memory manager's control.  Consult the
documentation provided with the memory manager software for
instructions on how to exclude this memory region.

DOS/Windows 3.x

2-8

Summary of Contents for DSP-200/300

Page 1: ...PCMCIA Asynchronous Adapter for PCMCIA Card Standard compatible machines User s Manual QUATECH INC TEL 330 665 9000 5675 Hudson Industrial Parkway FAX 330 665 9010 Hudson Ohio 44236 www quatech com IN...

Page 2: ...will Quatech Inc be liable for damages of any kind incidental or consequential in regard to or arising out of the performance or form of the materials presented herein and in the program s accompanyin...

Page 3: ...of Council Directive 89 336 EEC Standards to which Conformity is Declared EN50081 1 EN55022 EN50082 1 IEC 801 2 IEC 801 3 IEC 801 4 Type of Equipment Information Technology Equipment Equipment Class...

Page 4: ...00 Resource Settings in Windows 2000 4 2 Installing a DSP 200 300 Under Windows 2000 4 2 Windows 2000 3 6 Frequently Asked Questions 3 3 Changing Resource Settings with Device Manager 3 3 Viewing Reso...

Page 5: ...300provides four differential signal pairs two input and two output TxD RxD AUXOUT and AUXIN TxD and RxD are always present at the connector The AUXOUT and AUXIN signals can be used to support RTS CTS...

Page 6: ...This page intentionally left blank 2 1 DSP 200 300 Rev I and later User s Manual...

Page 7: ...t Swapping Allows automatic configuration of DSP 200 300 adapters upon insertion Hot Swapping Interfaces directly to Intel 82365SL and other PCIC compatible PCMCIA host adapters Interfaces to PCMCIA C...

Page 8: ...following line to the CONFIG SYS file DEVICE drive path DSP230CL SYS options where options are the DSP 200 300 Client Driver command line options discussed on the following pages 5 Save the CONFIG SY...

Page 9: ...0in decimal irq must be one of the following values 3 4 5 7 9 10 11 12 14 15 or 0 if no IRQ is desired If this option is omitted an interrupt level will be assigned by Card and Socket Services Ssocket...

Page 10: ...be disabled 2 1 2 2 Example 2 DEVICE C DSP 200 DSP230CL SYS b290 i11 In example 2 a single command line argument is provided The Client Driver will attempt to configure a DSP 200 300 inserted into any...

Page 11: ...ss assigned by Card and Socket Services and IRQ 10 If IRQ 10 is also unavailable the Client Driver will proceed to the third command line argument and attempt to configure the DSP 200 300 with a base...

Page 12: ...odify the operation of the generic client driver to disable the configuration of modem serial port cards Consult the Card and Socket Services documentation for availability and details of this feature...

Page 13: ...the device s it controls The DSP 200 300 Enabler does not support automatic configuration of adapters upon insertion more commonly referred to as Hot Swapping This means the adapter must be installed...

Page 14: ...is not used Waddress specifies the base address of the memory window required to configure the DSP 200 300 Set address D0 for a memory window at segment D000 address D8 for a memory window at segment...

Page 15: ...tructs the enabler to release the resources previously allocated to the DSP 200 300 When the R option is used any settings specified by the B I O and H options are ignored 2 2 1 1 Example 1 DSP230EN E...

Page 16: ...ill release the configuration used by the DSP 200 300 in socket 0 using a configuration memory window at segment D000 The base address and IRQ parameters are ignored and may be omitted 2 2 1 7 Example...

Page 17: ...the socket before the Enabler is invoked Some vendors number their sockets from 1 to N while other vendors number their sockets from 0 to N 1 For theDSP 200 300 Enabler the lowest socket number in the...

Page 18: ...This page intentionally left blank 3 1 DSP 200 300 Rev I and later User s Manual...

Page 19: ...llation CDs Insert the CD and click OK The DSP 200 300 PC Card should now be configured With the default configuration the DSP 200 300 s interrupt status register will be enabled the 16C750 UART s scr...

Page 20: ...particular ports 3 2 2Changing Resource Settings with Device Manager 1 Start the Windows 95 98 ME Device Manager 2 Double click on the hardware class Quatech Comm Adapters to list hardware devices in...

Page 21: ...y when data is being transmitted auto toggle Both RTS and DTR are controlled through the Modem Control Register of the 16750 When the Use Automatic Settings check box is enabled Windows 95 98 ME will...

Page 22: ...e Any Loopback 001A Scratch Pad 8x Always Enabled Any Loopback 0019 Scratch Pad Normal Always Enabled Any Loopback 0018 ISR 8x DTR Controlled Any Clocking 0017 ISR 8x DTR Controlled Any Handshaking 00...

Page 23: ...n at the bottom of the window Do not select a value that causes a conflict with any other installed hardware 8 If any changes have been made to the DSP 200 300 s configuration the card will automatica...

Page 24: ...This page intentionally left blank 4 1 DSP 200 300 Rev I and later User s Manual...

Page 25: ...modem control handshake option and the RS 422 485 output driver enable option for full and half duplex operation is supported 4 1 Installing a DSP 200 300 Under Windows 2000 1 Insert the Quatech COM C...

Page 26: ...4 Double click Serial Port Adapters 5 Double click Drivers 4 3 DSP 200 300 Rev I and later User s Manual...

Page 27: ...6 Double click on Windows 2000 XP for PCI PCMCIA ISA 7 Click on qserbrd and select open Windows 2000 4 4...

Page 28: ...in Windows 2000 use the system Device Manager To access Device Manager double click the System icon in the Windows 2000 control panel or click the My Computer icon on the Windows 2000 desktop with the...

Page 29: ...0 300 is Quatech DSP 200 300 PCMCIA Two Port RS 422 RS 485 Serial Adapter Figure 10 4 Open the Properties dialog for the DSP 200 300 device then click the Resources tab to view the Input Output Range...

Page 30: ...omputer icon on the Windows 2000 desktop with the right mouse button and select Properties from the pull down menu Click on the Hardware tab then click on the Device Manager Consult Windows 2000 on li...

Page 31: ...4 Open the Properties dialog for the DSP 200 300 device Figure 12 then click the Advanced tab to view the clock rate settings Windows 2000 4 8...

Page 32: ...rts hardware clock at double the standard rate The baud rate the port runs at will always be double the rate requested by the applications This mode is useful for legacy applicattions which cannot req...

Page 33: ...Windows 2000 4 10...

Page 34: ...you transmit sometimes called echo Always Receive Receive Control RTS routed to CTS AUXIN routed to RCLK and TCLK routed to AUXOUT Used to connect ports transmitting at different baud rates In order t...

Page 35: ...R 8x Always Enabled Any Handshaking 0010 ISR 8x DTR Controlled Any Loopback 0009 ISR 8x RTS Controlled Any Loopback 0008 ISR 8x Auto Toggle Any Loopback 0007 ISR Normal Always Enabled Any Clocking 000...

Page 36: ...TS Controlled Any Loopback 0027 Scratch Pad Normal Auto Toggle Any Loopback 0026 Scratch Pad 8x Always Enabled Any Loopback 0025 Scratch Pad Normal Always Enabled Any Loopback 0024 ISR 8x DTR Controll...

Page 37: ...ntion to the conflict information at the bottom of the window Do not select a value that causes a conflict with any other installed hardware 10 If any changes have been made to theDSP 200 300 s config...

Page 38: ...This page intentionally left blank 5 1 DSP 200 300 Rev I and later User s Manual...

Page 39: ...supports the DSP 200 300 only in block addressing mode To begin the installation open Windows Explorer and search for the Setup exe command to install the Quatech Device Manager See following Windows...

Page 40: ...double click the Quatech Device Manager icon on the desktop Device Manager Icon on Desktop 2 Click the Add button at the bottom of the Quatech Device Manager Window 5 3 DSP 200 300 Rev I and later Us...

Page 41: ...3 Follow the steps for the Add Quatech Hardware Wizard Windows NT 5 4...

Page 42: ...SP 200 300 PC Card should now be configured In the future Windows NT will automatically recognize and configure the DSP 200 300 Note Windows NT does not support Plug and Play for PCMCIA cards The PCMC...

Page 43: ...1 1 Auxiliary Channel RTS CTS Handshaking The RTS CTS handshake may be enabled so that RTS request to send is the auxiliary output signal on AUX OUT pin 1 and AUX OUT pin 6 Similarly CTS clear to send...

Page 44: ...TS from the 16C750 UART will be looped back to each other In addition the auxiliary output and input signals will be looped back to each other This configuration is shown below RS 422 485 16C550 UART...

Page 45: ...Duplex 16C550 RTS DTR NOTE One of these three options must be selected via software configuration Full duplex operation is the default mode Full Duplex MUX Figure 11 RS 422 485 Driver Enable Options I...

Page 46: ...ssing the PCMCIA Configuration Register on the DSP 200 300 CAUTION When operating in half duplex mode the transmitter output drivers must be disabled before receiving any information Failure to do so...

Page 47: ...nly to the external connector Any termination which is required must be added externally RS 422 485 Receiver Rt RXD RXD RS 422 485 Receiver Rt AUXIN AUXIN RS 422 100 ohm 1 2W resistor RS 485 60 ohms t...

Page 48: ...This page intentionally left blank 7 1 DSP 200 300 Rev I and later User s Manual...

Page 49: ...or into a standard D 9 female connector data terminal equipment DTE as shown in the figures below Standard D 9 Male Figure 14 DSP 200 300 Adapter Cable D 9 Female Connector 1 2 3 4 5 9 8 7 6 AUXOUT DA...

Page 50: ...This page intentionally left blank 8 1 DSP 200 300 Rev I and later User s Manual...

Page 51: ...face PCMCIA PC Card Standard 2 1 compliant Physical Dimensions Type II PCMCIA card 5mm Maximum Baud Rate 921 6K Power Requirements 5 volts 20 mA typical 30 mA maximum Connector Adapter to standard fem...

Page 52: ...DSP 200 300 User s Manual Revision 3 12 March 2004 P N 940 0075 312 Quatech Inc...