Adapters"
group or the QSP-200/300 model number does not appear, contact
Quatech Technical Support for further assistance.
6. Click on the
‘Quatech QSP-200/300 PCMCIA Four-Port RS-422/465 Serial
Adapter
’ item and then click on the button labeled
"Properties"
.
7. Un-check the box "use automatic settings". This keeps Windows from changing the
resource settings when the system is restarted.
8. Select a "Basic Configuration" from the list box. Each "Basic Configuration" is
associated with a specific set of handshake and output driver options as listed in the
table below (a functional description of these options are contained in the section
Hardware Information
).
9. If a change in I/O address and / or IRQ setting is required, select the resource to be
modified (I/O or IRQ) and select
"Change Settings"
. Make the desired changes and
then click on "OK". A shutdown of the system may be required to allow the settings
to change. If prompted for a shutdown, select the option which restarts Windows 95.
10. The QSP-200/300 will be automatically reconfigured to the desired settings.
11. The card is now ready for use.
QSP-200/300 User's Manual