QUATREAU TOUCH 
TYPE AA AIR GAP

*

————————————————————

T

he drain out device is an essential and 

mandatory component for Quatreau

®

 

tap installations.

•  Shown here (top right) connected to 

the tap Venturi™ on the boiling pipe 
feeding 

SmartTap

 or boiling chilled 

sparkling pipe feeding the 

TouchTap

.

•  It is designed to create an air gap 

preventing reverse migration of waste 
water into a potable water device.

•  The interconnection pipe must run 

downhill (as shown here) into the 
Airgap connection.

Stage 2

 provides a secondary non return 

valve in the grey adaptor whilst stage 2 
provides an air gap between water being 
drained off and the foul waste.

Stage 3

 is the Drain Out Kit connection 

saddle for 32mm or 40mm waste 
connection. Manual piercing device 
included in the kit.

Stage 1

 the Type AA airgap connection is 

a mandatory level of protection for potable 
water devices requiring a run off to drain. 

* Compliant with UK Water Regulations

T Y PE A A A IR G A P

Summary of Contents for PureH2O Touch

Page 1: ...BOILING CHILLED SPARKLING HOT COLD Touch INSTALLATION GUIDE...

Page 2: ...PRE INSTALLATION CHECK LIST 3 TYPE AA AIR GAP 4 INSTALLATION 5 UNPACKING YOUR EQUIPMENT 5 INSTALLING THE QUATREAU TOUCH TAP 5 INSTALLING THE QT553 B boiler control module 7 INSTALLING THE CS20 8 IMPO...

Page 3: ...ed Mains Cold Water that will be used to feed a cold supply to the system 4 Drainage An approved Type AA fitting air gap must be used for the Venturi waste Either a trapped upstand or drain clamp can...

Page 4: ...le water device The interconnection pipe must run downhill as shown here into the Airgap connection Stage 2 provides a secondary non return valve in the grey adaptor whilst stage 2 provides an air gap...

Page 5: ...and electrical connection that will be in a plastic bag inside the packing A contents list will explain what should be included and what the parts are used for PRIOR TO INSTALLATION WE RECOMMEND THAT...

Page 6: ...nel faces forward towards the user position 180 degrees to the sink Now you can tighten the nuts until you have a firm fixing on both sides The comms cable hangs down and will connect into the QT553 B...

Page 7: ...ust flow for mains hot and cold if the thermostatic valve is out of reach This will control the cold water mains feed that is fitted to the left rear low level fitting labeled cold mains inlet It will...

Page 8: ...he boiler unit at the back Push gently until it clicks in Connect the power lead but do not turn on at this stage QUATREAU TOUCH INSTALLING THE CS20 Before installation of the chiller unit refer to th...

Page 9: ...ontrol unit 3 Install Thermostatic mixing valve and set to maximum temperature then reduce by 1 2 turn for 40C set point Connect the hot and cold feeds with isolators 4 Install Drain off saddle with t...

Reviews: