background image

QUATRO    

Air Technologies Inc. 

11 

 

9- SPECIFICATIONS 

Nominal Airflow (Single Motor) 

110 CFM 

Nominal Airflow (Double Motor) 

220 CFM 

Nominal Airflow (Brushless Motor) 

280 CFM 

Approximate Dimensions: 

28.5" (724mm) High x 12.75" (324mm) Wide x 15.75" (400mm) Deep 

6” Filter Section Models 22” (508mm) High 

Voltage/Phase/Frequency, Current, Power  

Single Brush Type 115/1/60, 7 Amps, 825 Watts 

Single Brush Type 230/1/50, 4 amps, 750 Watts 

Double Brush Type 115/1/60, 12 Amps, 1650 Watts 

Double Brush Type 230/1/50, 8 amps, 1500 Watts (Operating at 60Hz) 

Brushless 115/1/60:  6.8 amps, 1100 Watts 

Brushless 230/1/50: 3.4 amps 1200 Watts (Operating at 60Hz) 

Approx. Weight: 

70lbs (27kg) w/o filters 

100lbs (45kg) with filters 

10- GENERAL REPLACMENT PARTS 

Qty 

Description 

Part 

Power Cord 120v 

E500 

Power Cord (Euro 230V) 

E130 

Remote Cable 

AE427 

Cover Gasket Roll (40') 

H006 

11- WARRANTY  

QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use 
and service for a period of one year from date of shipment.  QUATRO's obligation under this warranty shall be limited to 
replacing any parts, thereof, which shall be demonstrated to have been defective.  This is expressly in lieu of all other 
warranties, express or implied, including the warranties of merchantability and fitness. 
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall 
not be liable for any loss or damage.  No person, firm or corporation is authorised to assume for QUATRO any other liability 
in connection with the sale of these goods.  Equipment, parts and material manufactured by others and incorporated in 
QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO Air 
Technologies Inc. 

 

Conditions and Limitations: 

This warranty does not cover

 abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of 

God, fear wear, modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as 
well as operation of the equipment at voltages other than those specified by QUATRO Air Technologies Inc.

  

 

IMPORTANT NOTE FOR UNITS EQUIPPED WITH “INFINITY” MOTORS:

 In cases of heavy production 

(continuous 

hours of daily operation)

, the brushes on the INFINITY Motors may wear before the warranty is over.  

Please note this is NOT considered a warranty issue. Motor life is a function of hours used and filter maintenance. 
They are designed to operate 2000-3000 hours and then replaced.  

In some extreme cases motor life can even be less than 2000 hours and this is usually due to the system being run at a 
high pressure (dirty filters) for extended periods of time. 

 

Warning: 
This is a class A product. In domestic environment, this product may cause radio interference in which case the user may be 
required to take adequate measures. 

 

 

 

 

For Technical Assistance, call QUATRO Air Technologies inc. at 

(514) 630-4444 (in Montreal, Canada). 

 

Please ensure that you have your 

equipment serial number

 available when calling. 

 

Summary of Contents for 425L

Page 1: ...tors Instruction Maintenance Manual READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THE SYSTEM STORE THE MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE THIS MANUAL CONTAINS CRITICAL OPERATING INFORMATION WHICH IF NOT FOLLOWED COULD CAUSE DAMAGE TO THE SYSTEM NOT COVERED BY WARRANTY ...

Page 2: ...isture water or rain Use only on a grounded electrical circuit Do not install or operate the system in an enclosed space or against a wall Unit may overheat shut down Keep all objects at least 6 away from the casing especially the discharge grill All filters must be in place whenever this machine is in operation ALWAYS turn system on off switch to off and disconnect power prior to accessing unit r...

Page 3: ...ollowing page to understand the meanings of the LEDs and the alarms Alarms Status Conditions Alarm Mute Feature All alarms can be muted for a period of 8 hours OPERATING TIME After 8 hours the alarm will return and can be muted again When mute is enabled L1 Flashes the muted alarms stay SOLID The level of the alert will not be displayed until the 8 hour mute period is over To mute Press SPD UP DN ...

Page 4: ...g Slowly Beep Every Hour Filter Pressure Near Critical Service Becoming Urgent Replace Filters Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear See Filter Service Replacement Section For More Info Filter Service Replacement Instructions Flashing Slowly Beep Every Second Critical Pressure Unit Has Shutdown To Prevent Damage From Excess Pr...

Page 5: ... the AE427 QUATRO Universal Remote Cable QUATRO has some custom remote cables for specific applications Contact us for more info on available applications and part numbers The Quatro System supports Closed Contact 1 30V AC or DC remote operation as well as Remote Status signals Switching power to control the QUATRO System system remotely WILL NOT WORK and can damage the unit Temporary ON Mode Allo...

Page 6: ...ipment must be set or programmed to shut itself off when the Quatro Run signal is OPENED Contact your equipment manufacturer to verify if your equipment supports that function The status signals can either return a signal provided by your equipment or output a 12VDC or 12VDC depending on how the AE427 remote cable is wired The Quatro System uses a single common for both the Run Fault Signals To re...

Page 7: ...ollow the filter order on the inside of the access door This filter sequence can be customized for your application Disposal of both odour and particulate filters is the responsibility of the end user Please contact local authorities for proper and legal disposal of spent filters Odour Filter Refilling The odor filter does not have to be replaced It can be refilled with new filtration media FOR SY...

Page 8: ...ON 7 MOTOR SERVICE REPLACEMENT LED Diagnostic Table Service Motor s Alerts If Service Filter s alert is ON SOLID the motor s need to be serviced or replaced MOTOR ACCESS WARNING Switch unit off and unplug power cord from wall before servicing the motor s The motor s are accessed through the bottom access pane REMOVE ALL FILTERS BEFORE TURNING THE UNIT OVER TO ACCESS THE MOTORS Quick Change Brush M...

Page 9: ...ads located both sides of the motor access panel This should be done every time the brushes are changed for 2 motor units of ever second time for single motor units 6 Close motor access panel 7 For units with Basic Controls plug in power cord and run the unit with the hose disconnected for 20 minutes at minimum speed This is a break in period for the brushes and is required to properly seat the br...

Page 10: ...ASHING QUICKLY 6 Press SPEED DN 1 Time until Service Motor s LED is FLASHING 7 Press HOLD POWER button while Service Motor s LED is FLASHING unit is BEEPING continuously 8 Release when LED stops FLASHING stops BEEPING Replacement Motors Part 120V Quick Change SPH416 SPH426 AF416 AF426 Single AB001 230V Quick Change SPH415 SPH425 AF415 AF425 Single AB002 120V Infinity SPH426L AF426L Kit 2 Motors AB...

Page 11: ...ble for any loss or damage No person firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in QUATRO s equipment are warranted by QUATRO only to the extent of the original manufacturer s liability to QUATRO Air Technologies Inc Conditions and Limitations This warrant...

Page 12: ...QUATRO Air Technologies Inc 12 ...

Page 13: ...QUATRO Air Technologies Inc 13 ...

Page 14: ...QUATRO Air Technologies Inc 14 ...

Reviews: