QUATRO
Air Technologies Inc.
---------------------------------------------------------
Engineers Of Clean Air
--------------------------------------------------------
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454 website:
www.quatroair.com
info@quatroair.com
Operations & Maintenance Manual
CollectALL
MedEVAC MultiPure
PowerStation PS2
SHIPPED WITH THE UNIT (LOOSE):
Model
Ships with:
CollectALL
Open Filter Door: PowerCord, air inlet plate, clamps, Remote Hand-Switch
Outside the unit 12-ft long, 3” diameter hose
MedEVAC Multipure
Open Filter Door: PowerCord, air inlet plate, Remote Hand-Switch, (3) Rubber
hose cuffs (2 for 1.5” accessory, 1 for 2.5” accessory)
Outside the unit: 18-ft hose
PowerStation (PS2)
Open Filter Door: PowerCord, air inlet plate, milling Auto-Start Cable
Outside the unit: 6-ft long hose
INSTALLATION
1) Open filter door, remove plastic around HEPA filter (and Odor Filter if applicable)
2) Ensure filter bags are properly installed, fit into 2 tubes beneath the top of filter section
3) INSTALL CASTERS (WHEELS) IF THIS OPTION WAS PURCHASED (#AA037)
4) Plug Power Cordset to a grounded 120-volt wall outlet
4) Connect to applicable work-station/milling machine
START-UP
1) Press red POWER button on control panel to ensure unit STARTS
“System ON” LED illuminates, indicates unit is operating
2) Press POWER button again to switch unit OFF
3) You are now ready to operate
4) Connect remote hand-switch (PN AA375 or foot-pedal (PN AA175) to the remote
socket on the control panel to start unit remotely
If: “System ON” LED is OFF (indicates unit NOT operating)
If: “Remote/Standby” LED flashes (indicating unit is in WAITING MODE)
If: “Remote/Standby” LED ON (indicating unit is OPERATING)