Operations & Maintenance Manual 

PowerStation, PS6 Series 

   

 

INSTALLATION, FREE-STANDING MODEL 

The unit is shipped in the upside-down position, casters are factory installed, 2 models available, 
All items below are shipped in a separate box: 

Model 

Ships with: 

PS625-2370-0 
 

(2) F022 HEPA filters, (6) AG259 YELLOW filter bags, (4) Galv Filter Separators, 
O&M Manual, Hose and fittings are added separately depending on application. 

PS625-23AZ6GH 
 

(2) F022 HEPA filters, (6) AG149 WHITE filter bags, (2) Galv Filter Separators, O&M 
Manual, (2)inlet plates(3x1.5”dia),50ft 1.5”dia suction hose, 240v PowerCord(#E302),  
Foot-pedal (AA175), 

 

(6) Rubber hose fittings, (6) 2”wide x ½”thick gaskets for rubber hose fittings: 
  Connect to 1.5” dia: use hose directly 
  Connect to 2” dia: use Rubber Hose fittings to connect 
  Connect to 2.5” or 3”dia:  use ½” thick gaskets around Rubber hose Fittigns to make 
  up the dimension 

 

Your option to install unit on (6) stationery rubber feet or (4) mobile casters (install 2 
lockable casters in front) 

 

1)  Install Rubber feet or casters 
2)  Open filter door, remove plastic around HEPA filter, install HEPA filter, Grating and filter bags 
3)  Plug Power Cord to a grounded 240-volt wall outlet 
4)  Connect to individual workstations 

SYSTEM IS MORE EFFICIENT WHEN CONNECTING EACH WORKSTATION INDIVIDUALLY 

 

START-UP 

1) Plug the unit into a 220-240v wall outlet with the cord provided (socket is on side of unit) 
2) After 10seconds, switch ON using RED POWER button on control panel to ensure unit STARTS 

“System ON” LED illuminates, indicates unit is operating 

2) Press POWER button again to switch unit OFF 
3) You are now ready to operate 
4) Install Foot-Pedal (#AA175) into the db9 (9-pin socket on side of unit) to start/stop unit remotely 

If: “System ON” LED is OFF (indicates unit NOT operating) 
If: “Remote/Standby” LED flashes (indicating unit is in WAITING MODE) 

PS6 is shipped on a 
pallet, in an Upside-
Down Configuration 
 
Accessories shown 
on top are shipped in 
a box, placed on top 
of the unit

 

Summary of Contents for PowerStation PS6 Series

Page 1: ... dia use thick gaskets around Rubber hose Fittigns to make up the dimension Your option to install unit on 6 stationery rubber feet or 4 mobile casters install 2 lockable casters in front 1 Install Rubber feet or casters 2 Open filter door remove plastic around HEPA filter install HEPA filter Grating and filter bags 3 Plug Power Cord to a grounded 240 volt wall outlet 4 Connect to individual works...

Page 2: ...ck Easy Remote Start Stop Valves that reduce Dust Collector power consumption ASVs allow more suction to the active workstations by diverting air from the idle ones Principle of Operation 1 START STOP dust collector when you OPEN CLOSE valve 2 CLOSE valve when not using workstation OPEN valve when using dust collector 3 Install as many ASVs as you like Dust collector STARTS automatically if AT LEA...

Page 3: ...pect concealed damages inside the box indicate so on the transport companies shipping documents Single box c w all components required either on or inside the unit PRE START UP CHECKLIST a Check that all internal components are present and are adequately supported b Check that labels and serial numbers are present for future identification c Verify power supply compatibility with equipment 120 vol...

Page 4: ... will be OFF and unit will be ready to operate again Resetting Microprocessor After Filter Replacement WHILE Service Filters Led is OFF 1 Ensure motor access door is closed 2 Plug power back to the unit 3 When you Press POWER MOTOR WILL START 4 While motor is operating press hold SPEED UP DN simultaneously until unit BEEPS hold for 10 seconds when beeping continuously release 5 In this condition S...

Page 5: ...ower supply Circuit breaker popped Motor burnt Brushes worn Check breaker box RESET circuit breaker on unit panel Replace motor PN AB001 Replace Brushes PN AB112 Excessive noise Turbine impeller contacting housing Replace motor PN AB001 Insufficient airflow Obstruction in system Clogged filter Remove obstruction Replace filter Motor shuts off Input amperage too high Graphite crystal rods are consu...

Page 6: ...oming Urgent Replace Filters See Filter Service Replacement For More Info Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear Flashing Slowly Beep Every Second Critical Pressure Unit Has Shutdown To Prevent Damage From Excess Pressure Verify Blockage Remove Blockage Verify All Filters Clean Replace Filters Accordingly See Filter Service Rep...