© Quatro Air Technologies| MAY 2019 | All rights reserved |
iVAC Premium Series Operation and Maintenence Manual
Page 11
Controls
If there are any additional alarms when MUTED, mute will disable itself until muted again, then BOTH alarms will be
muted.
Muted alarms will only be displayed while the unit is in operation. If the unit is turned off and then on during the 8 hour
mute, the balance of the 8 hour mute will continue after the unit is turned on again.
LED Diagnostics Table R17.0 And Higher - iVac
Light
(LED)
Status
Audible
Alert
Condition
Description/Action
System
ON
LED 1
(L1)
SOLID
Unit is ON **
Fading
IN-OUT
Temporary ON Mode
POWER Button Had Been Used To Temporarily Turn Unit On While In
Remote Mode
See
T
emporary ON Mode
On Next Page
Flashing
Slowly
AUDIBLE ALERT MUTED
Alarm Condition MUTED, See L2, L3 Or L4 For Specific Alarm Condition
Service
Motors
LED 2 (L2)
SOLID
Beep Every
4 Hrs
Motor(s) Will Soon Need
Service
Quick Change Brush Motor(s) WILL SOON Require Brush Replacement
Infinity Brush Motor(s) WILL SOON Require Complete Replacement
Brushless Motor Is Almost At The End Of The Predicted Service Life
RESET ALERT After Service
"Filter Service and Replacement" on page 15
SOLID
Beep Every
15 Min
Motor(s) Service Becoming
Urgent
Quick Change Brush Motors ONLY: Replace Brushes ASAP And
RESET
ALERT
Motor Service and Replacement" on page 23
SOLID
Beep Every
5 Min
Motor(s) Service
Required
IMMEDIATELY
Quick Change Brush Motors ONLY: Replace Brushes IMMEDIATELY And
RESET ALERT
Motor Service and Replacement" on page 23
SOLID
Motor Alarm Muted
L1 Flashing Slowly
Replace Brushes OR Motor(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page
Motor Service and Replacement" on page 23
Service
Filter (s)
LED 3
(L3)
Flashing
Slowly
*Filter Pressure High
Try On Demand Filter Cleaning, Prepare To Service/Replace Filters
Filter Service and Replacement" on page 15
Flashing
Slowly
Beep Every
Hour
*Filter Pressure Near
Critical.
Service Becoming Urgent
Remove & Clean Main (Round) Filter. If Alarm Continues Either The Main
(Round) Filter Or The HEPA Filter Need To Be Replaced
Continued Operation May Result In Unit Shutdown.
High Pressure Causes Excess Motor Heat & Accelerates Brush Wear.
Filter Service and Replacement" on page 15
Flashing
Slowly
Beep Every
Second
*Critical Pressure
Unit Has Shutdown
To Prevent Damage From Excess Pressure
Verify Blockage – Remove Blockage
Verify All Filters – Clean/Replace Filters Accordingly
Filter Service and Replacement" on page 15
For More Info
SOLID
Beep Every
Hour
Filter(s) Service Life
Expired
Replace Filter(s) ASAP And RESET ALERT
Filter Service and Replacement" on page 15
SOLID
Filter Alarm Muted
L1 Flashing Slowly
Replace Filter(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page